Uncorrected volume calculation from pulse count data input
- Last UpdatedOct 28, 2025
- 1 minute read
-
If the pulse count has a value, then the Uncorrected Volume is calculated from it. After the Uncorrected Volume is calculated, the volume and energy will be calculated from the Uncorrected Volume.
-
If pulse count is 'null/0' and Uncorrected Volume has a value, then volume and energy are calculated from the Uncorrected Volume.
-
If the pulse count and Uncorrected Volume are null, the row is flagged with a problem.
-
If the pulse count is 0 and the Uncorrected Volume is null, then the Uncorrected Volume is calculated as 0. The volume and energy is then calculated from the resultant Uncorrected Volume.
Re-calculation on data edits
-
If you enter a value for pulse count that is not 'null/0', then Uncorrected Volume is calculated, and volume and energy is calculated from the resultant Uncorrected Volume.
-
If you enter a value of '0' for the pulse count and the Uncorrected Volume is null, then Uncorrected Volume is calculated as 0, and volume and energy is calculated from Uncorrected Volume.
-
If you enter a value of 'null/0' for pulse count and Uncorrected Volume has a value that is not 'null/0', then Uncorrected Volume is not calculated.
-
If you edit the Uncorrected Volume, then the pulse count is not re-calculated.