Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Measurement Advisor

Uncorrected volume calculation from pulse count data input

Uncorrected volume calculation from pulse count data input

  • Last UpdatedOct 28, 2025
  • 1 minute read
  1. If the pulse count has a value, then the Uncorrected Volume is calculated from it. After the Uncorrected Volume is calculated, the volume and energy will be calculated from the Uncorrected Volume.

  2. If pulse count is 'null/0' and Uncorrected Volume has a value, then volume and energy are calculated from the Uncorrected Volume.

  3. If the pulse count and Uncorrected Volume are null, the row is flagged with a problem.

  4. If the pulse count is 0 and the Uncorrected Volume is null, then the Uncorrected Volume is calculated as 0. The volume and energy is then calculated from the resultant Uncorrected Volume.

Re-calculation on data edits

  1. If you enter a value for pulse count that is not 'null/0', then Uncorrected Volume is calculated, and volume and energy is calculated from the resultant Uncorrected Volume.

  2. If you enter a value of '0' for the pulse count and the Uncorrected Volume is null, then Uncorrected Volume is calculated as 0, and volume and energy is calculated from Uncorrected Volume.

  3. If you enter a value of 'null/0' for pulse count and Uncorrected Volume has a value that is not 'null/0', then Uncorrected Volume is not calculated.

  4. If you edit the Uncorrected Volume, then the pulse count is not re-calculated.