Properties for gas quality (GQ): host calculated tab

Properties for gas quality (GQ): host calculated tab

  • Last UpdatedNov 20, 2025
  • 3 minute read

This tab is used to define the Gas Quality (GQ) Properties that are unique to a Host-Calculated GQ.

Note: You must ensure that the associated SCADA points are created in the SCADA system.

For this tab to be visible, the Analysis Source must be set to Host Calculated Analysis. These properties define where the input for the host calculation is read from and what type of host calculation is performed.

If the information cannot be retrieved from the SCADA points, alarms are generated in the Alarm and Event Summaries associated with the AVEVA Pipeline Operations for Gas information. This information is used by the Gas Quality Summary and Gas Quality Data Editor windows.

For more information, refer to the AVEVA Pipeline Operations for Gas documentation, as well as the The connection between AVEVA Pipeline Operations for Gas and AVEVA Measurement Advisor section in the SCADA Interface chapter of this document.

Analog points are configured in the RealTime database (RTDB). For more information about analog point configuration, refer to volume 1 of the RealTime Administrator documentation.

Section

Item

Description

Host Calculated Analysis

Generate history?

Select to generate hourly Historical information. This is calculated as an hourly average.

Generate daily history?

Select to generate daily Historical information. The daily history is calculated as a daily average.

Generate sampled history?

Select to collect an instantaneous spot sample. For example, if the sample was due to the taken at 12:19 PM, and the host-calculated value is reporting a value of 347.00, that would be the value sent to the Measurement system, even if over the course of the hour, the averaged data yielded a value of 434.00.

Sampled History Interval

The sampled history interval defines the frequency at which a sample will be taken. This is the frequency at which the host-calculated data is sent from the RealTime database to Measurement.

Calculate heating value

Select to calculate the heating value.

Compute cricodentherm

Select to compute the cricodentherm.

Heating value

Defines the analog point associated with the heating value.

Specific gravity

Defines the analog point associated with the specific gravity.

Carbon dioxide

Defines the analog point associated with carbon dioxide.

Nitrogen

Defines the analog point associated with nitrogen.

Hydrogen

Defines the analog point associated with hydrogen.

Sulphur

Defines the analog point associated with sulphur.

Hydrogen sulfide

Defines the analog point associated with hydrogen sulfide.

Water

Defines the analog point associated with water.

Helium

Defines the analog point associated with helium.

Oxygen

Defines the analog point associated with oxygen.

Carbon monoxide

Defines the analog point associated with carbon monoxide.

Argon

Defines the analog point associated with argon.

Methane

Defines the analog point associated with methane.

Ethane

Defines the analog point associated with ethane.

Propane

Defines the analog point associated with propane.

Normal butane

Defines the analog point associated with normal butane.

Isotopic butane

Defines the analog point associated with isotopic butane.

Normal pentane

Defines the analog point associated with normal pentane.

Isotopic pentane

Defines the analog point associated with isotopic pentane.

Neo pentane

Defines the analog point associated with neo pentane.

Hexane

Defines the analog point associated with hexane.

Hexane plus

Defines the analog point associated with hexane plus.

Heptane

Defines the analog point associated with heptane.

Octane

Defines the analog point associated with octane.

Nonane

Defines the analog point associated with nonane.

Decane

Defines the analog point associated with decane.

Wobbe Index

Defines the analog point that provides the Wobbe index information.

Carbonyl Sulfide

Defines the analog point associated with carbonyl sulfide.

Mercaptans

Defines the analog point associated with mercaptans.

Un-normalized Total

Defines the analog point associated with the un-normalized total.

Super Compressibility

Defines the analog point associated with supercompressibility.

Mole Total

Defines the analog point associated with the mole total.

Extended Host Calc Gas

Analysis

Water dewpoint

Defines the analog point that provides water dewpoint information.

Cricodentherm

Defines the analog point that provides the cricodentherm information.

Total sulphur

Defines the analog point that provides the total sulphur information.

Extended Host Calc Liquid

Analysis

Density

Defines the analog point that provides the density information.

BSW

Defines the analog point that provides the Base, Sediment, and Water (BSW) information.

Viscosity

Defines the analog point that provides the viscosity information.