AVEVA™ Measurement Advisor

Line Pack meter edit state

  • Last UpdatedDec 20, 2024
  • 1 minute read

When you make edits to your Line Pack meter data, the following occurs:

  • If Flow Time is edited, the Volume, Energy, Mass, and Instantaneous Volume will be calculated. The Edit State will be Edited.

  • If In Pressure is edited, the Volume, Energy, Mass, Pressure, and Instantaneous Volume will be calculated. The Edit State will be Edited.

  • If In Temperature is edited, the Volume, Energy, Mass, Temperature, and Instantaneous Volume will be calculated. The Edit State will be Edited.

  • If Out Pressure is edited, the Volume, Energy, Mass, Pressure, and Instantaneous Volume will be calculated. The Edit State will be Edited.

  • If Out Temperature is edited, the Volume, Energy, Mass, Temperature, and Instantaneous Volume will be calculated. The Edit State will be Edited.

  • If Instantaneous Volume is edited, calculate nothing. The Edit State will be Edited.

  • If Instantaneous Energy is edited, calculate nothing. The Edit State will be Edited.

  • If Volume is edited, the Energy and Mass will be calculated. The Edit State will be Manual Override.

  • If Mass is edited, calculate nothing. The Edit State will be Manual Override.

  • If Energy is edited, the Edit State will be set to Manual Override.

    Note: Inlet/outlet pressures are converted from gauge to absolute before calculation of the average pressure for a line pack meter.