Configure Measuring station properties to perform integer rounding during station balancing calculations
- Last UpdatedSep 19, 2024
- 1 minute read
Configure Measuring station properties to perform integer rounding during station balancing calculations
Integer rounding for the Volume and Energy data has been added to the station balancing calculations. This allows you to configure the station balance calculation to round the data when calculating the balance based on a configured precision profile. The data is rounded based on the number of decimal places configured for Volume and Energy in the configured Balance Precision Profile. The default selection is Balance Station Profile.
A new precision profile available for selection in the Balance Precision Profile has been added to the Precision summary to accommodate the integer rounding: Zero Precision. It is configured with zero decimal places for all numeric sets. It can be used to calculate the station volume balances with integer precision.
There are two rounding options available for selection in the Measuring station properties' Rounding Rule:
-
Round then Sum - This rounds the data that is being balanced, and then sum the data to calculate the balance.
-
Sum then Round - This will sum the data together to calculate the balance and then round the balance.
The default rounding rule is Round then Sum.