Configure a Coriolis meter
- Last UpdatedAug 21, 2025
- 2 minute read
The following procedure will guide you through the process of configuring the Coriolis meter.
Note: In order to access the Coriolis Meter tab, you must have selected a Metering method of Coriolis Meter on the Meter tab of the Meter Properties. For more information, refer to Meter tab.

To configure your coriolis meter
-
Specify your Data Source.
-
Specify your Volumetric Calculation method.
The recommended method is AGA-11 2013, which performs coriolis metering using the AGA-11 2013 calculation method. Selecting AGA-11 2013 will open the AGA-11 2013 tab. For more information, refer to Define how the AGA-11 2013 calculations are performed.
-
In the K factor field, configure the pulse count per unit mass of the Coriolis meter.
-
Provide the appropriate Meter Factor.
-
Select the Coriolis Type to define the type of meter:
-
Bent Tube - Bending Mode
-
Straight Tube - Bending Mode
-
Straight Tube - Radial Mode
Note: This is for information only. It is not used in any processing.
-
-
Define the Mass Low Flow Cut-Off to enter the mass flow rate below which any indicated flow by the meter is considered to be invalid.
Note: The Mass Low Flow Cut-Off values are measured in units of mass per second.
-
Define the Mass Pulse Low Flow Cut-Off to enter the mass pulse flow rate below which any indicated flow by the meter is considered to be invalid.
Note: The Mass Pulse Low Flow Cut-Off values are entered in units of mass pulse per second.