Comparing Linear Members

  • Last UpdatedJan 23, 2023
  • 1 minute read

The following data attributes are compared between the original model and the reference model:

  • Start and end of Pline defined by Cardinal Point

  • Orientation and Beta angle

  • Specification Reference

  • Material grade and reference

Importing a Linear Member also sets the Import date and time UDAs. On merging members the revision number, transfer number and code are updated.

The log file messages recording any differences are of two formats: in Brief mode the results are presented on one line; in Verbose mode you are told what the old value was and the new value is so that they can see how the model has been changed. Refer to Brief Format for further information about the brief log file format.

You may get a lot of apparent changes which may be caused by the failure to map the profile types between systems. The log file will indicate which profiles have not been mapped. It is advised that you resolve the Profile Mapping issues first before becoming too concerned with other changes recorded in the log file.

During the Import phase, an attempt is made to map the Cardinal Points in the incoming model with existing Plines that have been mapped onto them.