Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

Specifications

  • Last UpdatedJan 13, 2023
  • 1 minute read

HVAC specifications are much like piping specifications, AVEVA provide three ‘out of box’ specifications:

  • AVEVA-RECTANGULAR

  • AVEVA SIMDUCT-CLASS-C

  • AVEVA SIMDUCT-CLASS-F.

The functionality available from the AVEVA Specification window is identical to that previous described, refer to Specifications for further information.

Mandatory headings in the specification table are:

PSHA

Component shape - RECT, CIRC or FLAT.

PWID

Duct width or diameter for circular components.

PHEI

Duct height (for circular components set to 0).

Note:
In AVEVA Catalog - the POINTS for pHeight, pWidth (for circular). The PDShape must currently be set using the Attributes window (if it is not in the Catalog window).

Related Links
TitleResults for “How to create a CRG?”Also Available in