Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

Specifications

  • Last UpdatedJan 13, 2023
  • 1 minute read

HVAC specifications are much like piping specifications, AVEVA provide three ‘out of box’ specifications:

  • AVEVA-RECTANGULAR

  • AVEVA SIMDUCT-CLASS-C

  • AVEVA SIMDUCT-CLASS-F.

The functionality available from the AVEVA Specification window is identical to that previous described, refer to Specifications for further information.

Mandatory headings in the specification table are:

PSHA

Component shape - RECT, CIRC or FLAT.

PWID

Duct width or diameter for circular components.

PHEI

Duct height (for circular components set to 0).

Note:
In AVEVA Catalog - the POINTS for pHeight, pWidth (for circular). The PDShape must currently be set using the Attributes window (if it is not in the Catalog window).

Related Links