AVEVA E3D Design communicates with Rohr2 using ASCII files. These files are stored in a directory that is declared by the environment variable %R2STRESS%. In addition, a Project-specific environment variable, %xyzR2STRESS%, can be used ("xyz" is the project code).

If both environment variables are set and both directories exist, the Project-specific directory is used.

It is recommended to use the Project-specific environment variable because of Project-related settings and different displacement files for each Project.

The following file extensions are used by the interface to transfer data:

Extension

Description

Direction

.ntr

File with geometry data.

AVEVA E3D Design to Rohr2.

.ntrerror

Log file for transfer of geometry.

.r2hangprop

File with data for hanger points.

Rohr2 to AVEVA E3D Design.

.r2hangerror

Log file for hanger points.

.r2disp

File for displacement data.

E3D Hanger Type Description

An overview of the allowed Hanger Types is available. For further information, refer to Hanger Types.