Settings and Definitions
- Last UpdatedJan 24, 2023
- 1 minute read
AVEVA E3D Design communicates with Rohr2 using ASCII files. These files are stored in a directory that is declared by the environment variable %R2STRESS%. In addition, a Project-specific environment variable, %xyzR2STRESS%, can be used ("xyz" is the project code).
If both environment variables are set and both directories exist, the Project-specific directory is used.
It is recommended to use the Project-specific environment variable because of Project-related settings and different displacement files for each Project.
The following file extensions are used by the interface to transfer data:
|
Extension |
Description |
Direction |
|---|---|---|
|
.ntr |
File with geometry data. |
AVEVA E3D Design to Rohr2. |
|
.ntrerror |
Log file for transfer of geometry. |
|
|
.r2hangprop |
File with data for hanger points. |
Rohr2 to AVEVA E3D Design. |
|
.r2hangerror |
Log file for hanger points. |
|
|
.r2disp |
File for displacement data. |
E3D Hanger Type Description