TABLE ST UC305X305X240 ,/BS-UC305x305x240 ,,,0,-90

The GENSEC with spref ,/BS-UC305x305x240 is output as TABLE ST UC305X305X240 .

PRIS YD <depth*0.001> <width*0.001>, -BEAMS-SPEC/Rectangular_Profile, depth width, , 0, 90

The GENSEC is with spref /CONCRETE-BEAMS-SPEC/Rectangular_Profile, and despara 500 and 300, is output as PRIS YD 0.5 ZD 0.3.

UPTABLE 1 W<Heig>X<Widt>, /Profile/Variable-SPCO, despA Heig Widt , , 0, -90

The GENSEC is with spref /Profile/Variable-SPCO, and despara 100, 14 30, is output as UPT 1 W14X30.

Due to the definition of the UPT in section 1, the output is:

START USER TABLE

TABLE 1 c:\Staad Pro\Table1.std

END