XHBPCLA
- Last UpdatedFeb 11, 2025
- 1 minute read
Arguments
|
1 |
PCLA STYP(s) |
|---|---|
|
For tube ATTAs, single value (quoted if using TANS) |
|
|
For component ATTAs, space or / separated list for TEE, ELBO, BEND components (NONE if not applicable) |
|
|
2 |
Any other selectors (quoted if using TANS) |
|
3 |
COMP or TUBE |
|
4 |
Hanger Direction p-point (for TUBE). This p-point will be orientated to point in the direction of the hanger Rotation Direction p-point (for COMP). This p-point will be orientated to point in the perpendicular direction of BENDs or ELBOs. |
|
5 |
Angle flag. True if the component has a DDANG which needs to be deduced. |
|
6 |
Connection/Fitting instructions: |
|
ATTA: Sets PCLA height to distance P0 to P3 of ATTA |
|
|
FITH: Sets PCLA height to distance HH to HT |
|
|
FITP: Sets PCLA height to half pipe OD |
|
|
CONN: Does not set PCLA height |
|
|
7 |
Spec from which to select component: |
|
INSPEC: Select from current HSPEC |
|
|
PSPEC: Select from attached pipe PSPEC |
|
|
<gid>: Select from explicit specification |
Globals used
None
Globals set
|
!!CDSNHB.RTOVAL1 |
Derived RTO value at P1 end |
|---|---|
|
!!CDSNHB.RTOVAL2 |
Derived RTO value at P2 end |