Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

Branch and Hanger Specifications

  • Last UpdatedFeb 19, 2025
  • 1 minute read

Keywords

PSPE HSPE

Description

On creation of a Branch (or Hanger) these are normally the first attributes to be set. If the Specification of the Pipe has already been set, then this will automatically be cascaded down to Branch level when it is created. The PSPE attribute of a Branch controls all subsequent Component selection operations which choose a Component’s physical details from the stated Specification.

Examples

PSPEC /A35B8(At Pipe level)

The PSPE attribute of the Pipe and all subsequently created Branches will be set to /A35B8.

PSPEC /A15A2(At Branch level)

The PSPE attribute of the Branch will be set to /A15A2. All subsequent selection commands at that Branch or one of its Components will use that Specification by default.

Note:
The Specification named must be currently available to the designer.

Command Syntax

>-- PSPEcification  name -->