Allowable Dimension Ranges
- Last UpdatedJan 24, 2023
- 1 minute read
The support framework can be configured to set the minimum and maximum dimension values for each pipe bore allowed on the framework. This is achieved by setting the MdsRange: UDA of the template STRU.
Note:
Allowable dimensions and their effect on the framework differ between standards. Detailed
information about allowable dimensions for each standard are contained within the
SupportConfiguration.xml file. Refer to Dimension Customization for further information.