Fill Level Check
- Last UpdatedJan 23, 2023
- 2 minute read
Use to check the fill level check on the currently selected cableway branch, default is ON.

Load From
Use to populate the Select Cableway Branch list with all the cableway branches from the currently selected Site, Zone, Cableway and Cableway Branch.
A right click menu is also available from the Select Cableway Branch list:

|
Navigate to |
Navigates to the selected cableway branch in the model explorer. |
|
Highlight |
Highlights the currently selected cableway branch in the 3D view. |
Interference-Class Preferences
Use to check only the selected cables in segments, select from the available list:
-
average of all
-
POWER
-
INSTRUMENT
-
COMM
-
SIGNAL
-
CONTROL
-
WIRE
Note:
This list can be customized.
Current Branch
The branch points of the currently selected cableway branch is automatically displayed in the Branch Points. The elements are ordered from HEAD to TAIL and the associated fill levels are also displayed.
The colours on each individual cell correspond to the value entered in the Fill Check Utility Allowance field.
|
Green |
If a cell is coloured green, then the maximum fill of the branch is greater than the fill level. |
|
Yellow |
If a cell is coloured yellow, then the fill level of the branch point is within the fill check allowance to the maximum fill of the cableway branch. |
|
Red |
If a cell is coloured red, then the fill level of the branch exceeds the maximum fill of the cableway branch. |
A right click menu is also available from the Branch Points list:
|
Navigate to |
Navigates to the selected branch point in the Model Explorer. |
|
List of Cables |
Displays the List of Cables window with the selected branch point. |
|
Export to Excel |
Exports the Branch Points list data to Excel. |
When a branch point is selected from the list, graphical aids are displayed in the 3D view with the correct tag and position of the selected branch point.
Explain Fill Levels
Use to view an explanation of connections and fill levels.

Connections
Any valid connections are automatically displayed, if there are no valid connections No Connections Associated is displayed.
Note:
If the current element is a RATTA, RNODE, HATTA or TATTA when the Fill Levels window is first initialized the branch point is automatically selected.