Piping Settings
- Last UpdatedFeb 14, 2025
- 4 minute read
The Component part of the Piping Application Defaults window sets the default settings on the Piping Component Editor window.

|
Snap distance |
Sets the default snap distance (the minimum distance between the end of a component and the placement of a new component between which an automatic connection occurs) when creating a component. The selection is connected to the nearest component if placed within the set snap distance. The default is 2 * OD. |
|
Use tube tolerance |
Uses a pre-set Data Consistency specific tube length to ensure the pipe is placed correctly. |
|
Minimum tube length |
Sets the minimum tube distance between two components, the default is 100mm. Note: |
|
Use tube tolerance |
Uses pre-set Data Consistency specific tube length to ensure the pipe is placed correctly. |
|
Note:
|
|
|
Auto align |
Newly created components are aligned to the previous component automatically. |
|
Auto create |
The software determines if there is a requirement for associated components by default (for example, the associated components for a valve are a gasket and a flange). |
|
Select adjacent out of specification |
An alternative specification component can be used. |
|
Skip connected components |
The piping application determines which components are connected, then positions the creation point approximately. |
|
Multiple slope functionality |
Displays the point direction option on the Piping Component Editor window. |
|
Non standard branch connections |
Sets the defaults for the non-standard branch connections. |
|
Boss connections not allowed in tube |
For pipe tappings, specifies the boss type connections (for example, olets, half couplings, welded bosses) that can only be used on fittings and excluded from the tube. |
The Pipe/Branch part of the Piping Application Defaults window sets the default pipe editor settings on the Piping Component Editor window.

|
Sort piping specification list |
Sorts the piping specification list alphabetically. |
|
Auto create gaskets and flanges at branch |
On creation of a component, gaskets and flanges are automatically created. |
The Reselection part of the Piping Application Defaults window sets the default component selection settings on the Piping Component Editor window.

|
Descriptions |
Sets the display of the Description in the Component Type List from the Select and Reselect tabs. |
|
Tag component |
Sets the display value for the component tag in the 3D graphical view. |
|
Tag constraints |
When a component is selected, adjacent constrained components are highlighted in the 3D graphical view. |
|
Auto reconnect |
Reconnects components that are modified using the Reselect tab. Reconnection errors display in the Errors tab. |
|
Reconnect free ends |
Reconnects the branch head or branch tail if reselection of a component results in disconnection. |
|
Ignore positioned |
Ignores positioned components. Positioned components will normally not be moved when reconnected. |
The Laser Data part of the Piping Application Defaults window sets the default settings for laser settings on the Piping Component Editor window.

|
Direction rounding |
Rounds to an orthogonal direction (ENUWSD) for each component from the laser pick. |
|
Tolerance |
Tolerance of the direction. |
The Direction Display part of the Piping Application Defaults window sets the default display settings on the Piping Component Editor window.

|
Default ISO view |
Sets the default ISO view of elements displayed in the 3D graphical view. The ISO view updates depending on the type of the current project as well as the coordinate system. If the current project is PLANT and the coordinates are ENU, the default ISO view is North. If the current project is PLANT and the coordinates are XYZ, the default ISO view is Y. If the current project is MARINE and the coordinates are ENU, the default ISO view is East. if the current project is MARINE and the coordinates are XYZ, the default ISO view is X. |