Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

Setting Obstruction Representation for Cableways

  • Last UpdatedFeb 19, 2025
  • 1 minute read

Keywords

REPRESENTATION CABLEWAY OBSTRUCTION ON/OFF TRANSLUCENCY

Description

Cableway Obstructions are often given Representation settings which render them invisible. Setting the Representation of OBST On forces the system to override Representation settings and show all of the primitives, regardless of the other settings.

This has the effect of considering all primitives which have an obstruction level greater than zero. The graphics display is not updated instantly. Use the REPResentation UPDATE command to make any changes visible.

To avoid obscuring the view in colour-shaded mode, obstructions can be shown as translucent, the degree of translucency being controllable.

Examples

REPR CABLEWAY OBST ON

REPR CABLEWAY OBST OFF

REPR CABLEWAY OBST ON TRANSLUCENCY 25

Command Syntax

> REPResentation--CABLEWAY--OBSTruction -+- ON - TRANSLucency - value --.

                                         |                              |

                                         ‘- OFF ------------------------+->

Note:
value must be in the range 0‑99: the actual translucency will be set to the nearest of 25, 50, 75 or 87 (99 = transparent; 0 = opaque).

Querying

Q REPR CABLEWAY OBST TRANSL

Queries translucency setting for obstructions