Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

Error Messages

  • Last UpdatedFeb 19, 2025
  • 6 minute read

This chapter lists error messages specific to Model. These messages have a message number beginning with 61. Any other messages that may be output are not described here as they are not specific to Model.

Note:
In the following element_identifier denotes an element name or (for unnamed elements) an element reference number. The latter is a ‘system’ number which is assigned automatically whenever an element is created.

(61:1)

Unable to calculate the orientation

(61:2)

element_identifier is not a piping or a hanger component or has not been positioned oriented or selected.

(61:3)

element_identifier is not a branch or piping component

(61:4)

element_identifier is not a hanger or hanger component

(61:5)

Unable to position element_identifier

(61:6)

element_identifier does not have a position

(61:7)

Unable to orientate element_identifier

(61:8)

element_identifier does not have an orientation

(61:9)

Unable to set the head position of element_identifier

(61:10)

Unable to set the tail position of element_identifier

(61:11)

Unable to set the head direction of element_identifier

(61:12)

Unable to set the tail direction of element_identifier

(61:13)

Trying to connect element_identifier to itself

(61:14)

Unable to set the head reference of element_identifier

(61:15)

Unable to set the tail reference of element_identifier

(61:16)

Current element does not have a head or a tail attribute

(61:17)

Default orientation only available for piping and hanger components.

(61:18)

Default orientation cannot be found. Previous element either not positioned and oriented or not selected.

(61:19)

Direction undefined for towards origin of current element

(61:20)

Current element type unsuitable for DIRECTION command

(61:21)

SPREF can only be selected for a piping or hanger component

(61:22)

LSTUBE can only be selected for a piping component

(61:23)

HSTUBE can only be selected for a BRANCH

(61:24)

LSROD can only be selected for a hanger component

(61:25)

HSROD can only be selected for a HANGER

(61:26)

TUBE can only be selected for a BRANCH or a piping component

(61:27)

ROD can only be selected for a HANGER or a hanger component

(61:28)

Only BRANCHs, HANGERs, and piping and hanger components can be selected

(61:29)

element_identifier is not a SPEC

(61:30)

element_identifier is not a SPCOM

(61:31)

Cannot find SPCOM name

(61:32)

Appending name to specification name gives a name of more than 50 characters.

(61:33)

Angle attributes can only be given values between -180 and +180 degrees.

(61:34)

Degenerate orientation specified

(61:35)

Pins cannot be used for connecting piping or hanger components

(61:36)

Reconnecting element_identifier

(61:37)

Connection to element_identifier is invalid (HREF / TREF do not point back to nozzle)

(61:38)

element_identifier is locked, reconnection fails

(61:39)

element_identifier is in a read-only database, reconnection fails

(61:40)

Plane parallel to movement direction

(61:41)

Default movement direction only available for piping and hanger components.

(61:42)

Default movement direction not available. Previous element either not positioned and oriented or not selected.

(61:43)

ARRIVE / LEAVE ppoint cannot be determined. Current element has probably not been selected.

(61:44)

Default movement origin cannot be determined.

(61:45)

BOP and TOP can only be used with piping and hanger components.

(61:46)

DIRECTION command only operates on ppoints of the current element

(61:47)

Bad DIRECTION - zero degree angle specified

(61:48)

Point set does not allow variable angle. Angle is unchanged, direction is in correct plane.

(61:49)

Unable to achieve specified direction - probably due to unconventional pointset

(61:50)

Pin numbers must be in the range 1 to 10

(61:51)

Unable to position pin integer

(61:52)

Unable to orientate pin integer

(61:53)

Unable to copy the marker

(61:75)

element_identifier is not a branch, reconnect fails

(61:76)

Connection to a database that is not open, reconnection fails

(61:77)

Cannot find P-point 1 - Nozzle Catalog reference probably not set

(61:78)

Reconnect not allowed at WORLD or GPWL level

(61:79)

element_identifier cannot own nozzles

(61:80)

Cannot access SPCOM from which to reselect

(61:81)

To position the HEAD / TAIL of a branch or hanger use POS / MOVE PH / PT / HH / HT ...

(61:82)

BOP / TOP cannot be used on a HEAD / TAIL that has not been positioned

(61:83)

Default clearance is only available for piping or hanger components

(61:84)

Shear attributes can only be given values between -89 and +89 degrees.

(61:85)

element_identifier cannot be flipped - it does not have ARRIVE and LEAVE attributes.

(61:86)

Warning - Angle is greater than maximum specified in SPREF

(61:87)

Warning - Angle is less than minimum specified in SPREF

(61:88)

SPREF not found or unset

(61:89)

element_identifier does not have a Local-axes attribute

(61:120)

Too many views shown

(61:121)

Form name too word for screen

(61:122)

Unable to set form gadget value or gadget not found

(61:123)

Form name not found

(61:125)

Gadget name not found

(61:126)

Item invalid as contents of view

(61:127)

Form name already shown

(61:128)

Form name may not be hidden

(61:129)

Cannot open Recreate file

(61:130)

File error while restoring data - RESTORE aborted

(61:131)

File error while restoring data - please exit from module and reenter

(61:132)

Unable to RESTORE - databases modified since module state SAVEd

(61:133)

Unable to SAVE - cannot access SAVE file

(61:134)

Unable to SAVE - SAVE file already in use

(61:135)

Unable to RESTORE - SAVE file already in use

(61:136)

Unable to RESTORE - cannot access SAVE file

(61:137)

Unable to RESTORE - cannot find SAVE file

(61:138)

Unable to RESTORE - current database files are not those which were in use when module state SAVEd

(61:139)

Unable to RESTORE - module version number/screen size/font size is not the same as SAVE file

(61:140)

Does the user wish to save changes?

(61:150)

Only piping components, nozzles and equipments can be dragged

(61:151)

element_identifier is connected to element_identifier which is in a read only database. This connection will be broken by drag.

(61:152)

element_identifier has a connection to an unknown element. This connection will be broken by drag.

(61:153)

element_identifier is locked, drag aborted

(61:154)

The connection from element_identifier to element_identifier will be broken by drag.

(61:155)

Attachment points can only be dragged if they have been positioned and oriented

(61:160)

Spec is not set up correctly for CHOOSE command

(61:161)

element_identifier is not a piping component

(61:162)

SPEC does not contain word elements

(61:163)

SPEC does not contain correct bore structure for CHOOSE

(61:164)

SPEC does not contain elements matching given criteria

(61:165)

Previous component, element_identifier, has zero bore

(61:166)

Unforced Connections are word

(61:167)

Forced Connections are word

(61:168)

Connections are OFF

(61:169)

Warning - Requested bore value does not match current bore word

(61:175)

HOFFSET must be positive (not zero)

(61:190)

Fatal error detected by Graphics Package forcing a return to Monitor module

(61:191)

Are your databases to be updated with the changes made this session

(Y or N)

(61:192)

Fatal error detected by SPLASH forcing a return to Monitor module

(61:193)

WARNING - System storage area value % full. Remove items from drawlist to avoid fatal error.

(61:194)

WARNING - Graphics storage area value % full.

(61:199)

Cannot access directory name

(61:201)

No more than 20 items can be given to AUTO

(61:206)

XR and YR values must be in the range 0 to 1.0.

(61:207)

Specified region is too narrow.

(61:208)

Illegal autolimits produced. (Does it have any primitives?)

(61:209)

Mix values for colours are percentages (0 - 100)

(61:211)

Only colours 1 to integer may be assigned to pens

(61:220)

Failed to connect.

(61:221)

Cannot calculate default orientation.

(61:225)

Usable colours are system colours plus user colours 1 to integer

(61:226)

Autolimits may only be set for graphic views, Please select a graphics view and retry

(61:230)

Error reading from plotfile ..

(61:231)

Unrecognised code in plotfile

(61:272)

Already using file - name for alpha output

(61:273)

Cannot open alpha output file

(61:274)

No alpha output file in use.

(61:275)

Already using log file - name

(61:276)

Cannot open log file

(61:278)

No log file in use.

(61:303)

Direction cannot be calculated between two design points with the same position - UP is assumed

(61:304)

Position cannot be calculated as lines are parallel - first point given is assumed

(61:305)

Position cannot be calculated as line and plane are parallel - first point given is assumed

(61:306)

Angle cannot be calculated as two points are coincident - zero assumed

(61:307)

Only significant and drawable elements can be tagged by type

(61:351)

The WORLD and GPWLs cannot be added / removed. SITEs can only be added using ’ADD SITE’ in a setup context.

(61:355)

No more than ten elements can be added at one time

(61:357)

element_identifier is not a SITE

(61:358)

Only SITEs or ZONEs can be specified for ADD WITHIN. The default is all sites in the multiple database.

(61:461)

Hit radius must be at least 1mm.

(61:462)

Hit radius must be no more than 100mm.

(61:463)

Working grid must be at least 1mm.

(61:471)

Cursor abandoned

(61:495)

Form name may not be changed

(61:499)

F&M: Cannot swap parent of a blocking form

(61:561)

Workstation screen is not available, using TTY

(61:564)

Cursor input not allowed on alpha device

(61:565)

Point entered is not in a suitable view

(61:599)

Forms may not be updated

(61:800)

Reference DETAIL not set

(61:820)

SKEY not set

(61:830)

SKEY TSFL is used with generic type TEE, not TRAP

(61:840)

SKEY element_identifier not known. Assumed to be user defined

Related Links