Error Messages
- Last UpdatedFeb 19, 2025
- 6 minute read
This chapter lists error messages specific to Model. These messages have a message number beginning with 61. Any other messages that may be output are not described here as they are not specific to Model.
Note:
In the following element_identifier denotes an element name or (for unnamed elements) an element reference number. The latter is a ‘system’ number which is assigned automatically whenever an element
is created.
|
(61:1) |
Unable to calculate the orientation |
|
(61:2) |
element_identifier is not a piping or a hanger component or has not been positioned oriented or selected. |
|
(61:3) |
element_identifier is not a branch or piping component |
|
(61:4) |
element_identifier is not a hanger or hanger component |
|
(61:5) |
Unable to position element_identifier |
|
(61:6) |
element_identifier does not have a position |
|
(61:7) |
Unable to orientate element_identifier |
|
(61:8) |
element_identifier does not have an orientation |
|
(61:9) |
Unable to set the head position of element_identifier |
|
(61:10) |
Unable to set the tail position of element_identifier |
|
(61:11) |
Unable to set the head direction of element_identifier |
|
(61:12) |
Unable to set the tail direction of element_identifier |
|
(61:13) |
Trying to connect element_identifier to itself |
|
(61:14) |
Unable to set the head reference of element_identifier |
|
(61:15) |
Unable to set the tail reference of element_identifier |
|
(61:16) |
Current element does not have a head or a tail attribute |
|
(61:17) |
Default orientation only available for piping and hanger components. |
|
(61:18) |
Default orientation cannot be found. Previous element either not positioned and oriented or not selected. |
|
(61:19) |
Direction undefined for towards origin of current element |
|
(61:20) |
Current element type unsuitable for DIRECTION command |
|
(61:21) |
SPREF can only be selected for a piping or hanger component |
|
(61:22) |
LSTUBE can only be selected for a piping component |
|
(61:23) |
HSTUBE can only be selected for a BRANCH |
|
(61:24) |
LSROD can only be selected for a hanger component |
|
(61:25) |
HSROD can only be selected for a HANGER |
|
(61:26) |
TUBE can only be selected for a BRANCH or a piping component |
|
(61:27) |
ROD can only be selected for a HANGER or a hanger component |
|
(61:28) |
Only BRANCHs, HANGERs, and piping and hanger components can be selected |
|
(61:29) |
element_identifier is not a SPEC |
|
(61:30) |
element_identifier is not a SPCOM |
|
(61:31) |
Cannot find SPCOM name |
|
(61:32) |
Appending name to specification name gives a name of more than 50 characters. |
|
(61:33) |
Angle attributes can only be given values between -180 and +180 degrees. |
|
(61:34) |
Degenerate orientation specified |
|
(61:35) |
Pins cannot be used for connecting piping or hanger components |
|
(61:36) |
Reconnecting element_identifier |
|
(61:37) |
Connection to element_identifier is invalid (HREF / TREF do not point back to nozzle) |
|
(61:38) |
element_identifier is locked, reconnection fails |
|
(61:39) |
element_identifier is in a read-only database, reconnection fails |
|
(61:40) |
Plane parallel to movement direction |
|
(61:41) |
Default movement direction only available for piping and hanger components. |
|
(61:42) |
Default movement direction not available. Previous element either not positioned and oriented or not selected. |
|
(61:43) |
ARRIVE / LEAVE ppoint cannot be determined. Current element has probably not been selected. |
|
(61:44) |
Default movement origin cannot be determined. |
|
(61:45) |
BOP and TOP can only be used with piping and hanger components. |
|
(61:46) |
DIRECTION command only operates on ppoints of the current element |
|
(61:47) |
Bad DIRECTION - zero degree angle specified |
|
(61:48) |
Point set does not allow variable angle. Angle is unchanged, direction is in correct plane. |
|
(61:49) |
Unable to achieve specified direction - probably due to unconventional pointset |
|
(61:50) |
Pin numbers must be in the range 1 to 10 |
|
(61:51) |
Unable to position pin integer |
|
(61:52) |
Unable to orientate pin integer |
|
(61:53) |
Unable to copy the marker |
|
(61:75) |
element_identifier is not a branch, reconnect fails |
|
(61:76) |
Connection to a database that is not open, reconnection fails |
|
(61:77) |
Cannot find P-point 1 - Nozzle Catalog reference probably not set |
|
(61:78) |
Reconnect not allowed at WORLD or GPWL level |
|
(61:79) |
element_identifier cannot own nozzles |
|
(61:80) |
Cannot access SPCOM from which to reselect |
|
(61:81) |
To position the HEAD / TAIL of a branch or hanger use POS / MOVE PH / PT / HH / HT ... |
|
(61:82) |
BOP / TOP cannot be used on a HEAD / TAIL that has not been positioned |
|
(61:83) |
Default clearance is only available for piping or hanger components |
|
(61:84) |
Shear attributes can only be given values between -89 and +89 degrees. |
|
(61:85) |
element_identifier cannot be flipped - it does not have ARRIVE and LEAVE attributes. |
|
(61:86) |
Warning - Angle is greater than maximum specified in SPREF |
|
(61:87) |
Warning - Angle is less than minimum specified in SPREF |
|
(61:88) |
SPREF not found or unset |
|
(61:89) |
element_identifier does not have a Local-axes attribute |
|
(61:120) |
Too many views shown |
|
(61:121) |
Form name too word for screen |
|
(61:122) |
Unable to set form gadget value or gadget not found |
|
(61:123) |
Form name not found |
|
(61:125) |
Gadget name not found |
|
(61:126) |
Item invalid as contents of view |
|
(61:127) |
Form name already shown |
|
(61:128) |
Form name may not be hidden |
|
(61:129) |
Cannot open Recreate file |
|
(61:130) |
File error while restoring data - RESTORE aborted |
|
(61:131) |
File error while restoring data - please exit from module and reenter |
|
(61:132) |
Unable to RESTORE - databases modified since module state SAVEd |
|
(61:133) |
Unable to SAVE - cannot access SAVE file |
|
(61:134) |
Unable to SAVE - SAVE file already in use |
|
(61:135) |
Unable to RESTORE - SAVE file already in use |
|
(61:136) |
Unable to RESTORE - cannot access SAVE file |
|
(61:137) |
Unable to RESTORE - cannot find SAVE file |
|
(61:138) |
Unable to RESTORE - current database files are not those which were in use when module state SAVEd |
|
(61:139) |
Unable to RESTORE - module version number/screen size/font size is not the same as SAVE file |
|
(61:140) |
Does the user wish to save changes? |
|
(61:150) |
Only piping components, nozzles and equipments can be dragged |
|
(61:151) |
element_identifier is connected to element_identifier which is in a read only database. This connection will be broken by drag. |
|
(61:152) |
element_identifier has a connection to an unknown element. This connection will be broken by drag. |
|
(61:153) |
element_identifier is locked, drag aborted |
|
(61:154) |
The connection from element_identifier to element_identifier will be broken by drag. |
|
(61:155) |
Attachment points can only be dragged if they have been positioned and oriented |
|
(61:160) |
Spec is not set up correctly for CHOOSE command |
|
(61:161) |
element_identifier is not a piping component |
|
(61:162) |
SPEC does not contain word elements |
|
(61:163) |
SPEC does not contain correct bore structure for CHOOSE |
|
(61:164) |
SPEC does not contain elements matching given criteria |
|
(61:165) |
Previous component, element_identifier, has zero bore |
|
(61:166) |
Unforced Connections are word |
|
(61:167) |
Forced Connections are word |
|
(61:168) |
Connections are OFF |
|
(61:169) |
Warning - Requested bore value does not match current bore word |
|
(61:175) |
HOFFSET must be positive (not zero) |
|
(61:190) |
Fatal error detected by Graphics Package forcing a return to Monitor module |
|
(61:191) |
Are your databases to be updated with the changes made this session (Y or N) |
|
(61:192) |
Fatal error detected by SPLASH forcing a return to Monitor module |
|
(61:193) |
WARNING - System storage area value % full. Remove items from drawlist to avoid fatal error. |
|
(61:194) |
WARNING - Graphics storage area value % full. |
|
(61:199) |
Cannot access directory name |
|
(61:201) |
No more than 20 items can be given to AUTO |
|
(61:206) |
XR and YR values must be in the range 0 to 1.0. |
|
(61:207) |
Specified region is too narrow. |
|
(61:208) |
Illegal autolimits produced. (Does it have any primitives?) |
|
(61:209) |
Mix values for colours are percentages (0 - 100) |
|
(61:211) |
Only colours 1 to integer may be assigned to pens |
|
(61:220) |
Failed to connect. |
|
(61:221) |
Cannot calculate default orientation. |
|
(61:225) |
Usable colours are system colours plus user colours 1 to integer |
|
(61:226) |
Autolimits may only be set for graphic views, Please select a graphics view and retry |
|
(61:230) |
Error reading from plotfile .. |
|
(61:231) |
Unrecognised code in plotfile |
|
(61:272) |
Already using file - name for alpha output |
|
(61:273) |
Cannot open alpha output file |
|
(61:274) |
No alpha output file in use. |
|
(61:275) |
Already using log file - name |
|
(61:276) |
Cannot open log file |
|
(61:278) |
No log file in use. |
|
(61:303) |
Direction cannot be calculated between two design points with the same position - UP is assumed |
|
(61:304) |
Position cannot be calculated as lines are parallel - first point given is assumed |
|
(61:305) |
Position cannot be calculated as line and plane are parallel - first point given is assumed |
|
(61:306) |
Angle cannot be calculated as two points are coincident - zero assumed |
|
(61:307) |
Only significant and drawable elements can be tagged by type |
|
(61:351) |
The WORLD and GPWLs cannot be added / removed. SITEs can only be added using ’ADD SITE’ in a setup context. |
|
(61:355) |
No more than ten elements can be added at one time |
|
(61:357) |
element_identifier is not a SITE |
|
(61:358) |
Only SITEs or ZONEs can be specified for ADD WITHIN. The default is all sites in the multiple database. |
|
(61:461) |
Hit radius must be at least 1mm. |
|
(61:462) |
Hit radius must be no more than 100mm. |
|
(61:463) |
Working grid must be at least 1mm. |
|
(61:471) |
Cursor abandoned |
|
(61:495) |
Form name may not be changed |
|
(61:499) |
F&M: Cannot swap parent of a blocking form |
|
(61:561) |
Workstation screen is not available, using TTY |
|
(61:564) |
Cursor input not allowed on alpha device |
|
(61:565) |
Point entered is not in a suitable view |
|
(61:599) |
Forms may not be updated |
|
(61:800) |
Reference DETAIL not set |
|
(61:820) |
SKEY not set |
|
(61:830) |
SKEY TSFL is used with generic type TEE, not TRAP |
|
(61:840) |
SKEY element_identifier not known. Assumed to be user defined |