Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

Macros to Create Specification References

  • Last UpdatedJan 24, 2023
  • 1 minute read

Write a simple macro to create a Specification reference for the catalogue components created above.

myUDSpec

/ My-udHVACspec setst

tail

-- ----------------------------

NEW SELEC */3ways setst

DESC 'Rectangular Threeways'

QUES SPEC

TANS 'THRE'

TDEF 'NONE'

TQUES 'Specific'

NEW SPCOMPONENT */Y-Type1

TANS 'Y Type1'

Catref /My-Y-Type-3-Way1

Detref /My-Y-Type-3-Way1-Detail

NEW SPCOMPONENT */Y-Type2

TANS 'Y Type2'

Catref /My-Y-Type-3-Way2

Detref /My-Y-Type-3-Way2-Detail

NEW SPCOMPONENT */Y-Type3

TANS 'Y Type3'

Catref /My-Y-Type-3-Way3

Detref /My-Y-Type-3-Way3-Detail

NEW SPCOMPONENT */Angled-Type1

TANS 'Angled Type1'

Catref /My-Angled-Type-3-Way1

Detref /My-Angled-Type-3-Way1-Detail

NEW SPCOMPONENT */Angled-Type2

TANS 'Angled Type2'

Catref /My-Angled-Type-3-Way2

Detref /My-Angled-Type-3-Way2-Detail

NEW SPCOMPONENT */Angled-Type3

TANS 'Angled Type3'

Catref /My-Angled-Type-3-Way3

Detref /My-Angled-Type-3-Way3-Detail

Reminder:

  • SPWL %purp HVAC, SPEC %purp FITT to appear in the HVAC User Defined Fittings form.

  • Each level of SELE with %tquestion and %tans causes a further level of questions in the HVAC UD Fittings form.

  • Beware that a too lengthy %tans may prevent it from fitting into the form.