Populate Spec Headings
- Last UpdatedJan 13, 2023
- 3 minute read
Use the Headings window to build the Headings row of the new Specification.

Click Add Headings to display the Headings sub window.

The Questions table to the left of the window lists all the current heading columns of the Specification.
Add, remove and re-organise the order of columns to be included in the Specification.
|
|
Click to add a column to the Specification |
|
|
Click to remove the currently selected heading from the Specification |
|
|
Click to move the currently selected heading up the list (changing the order the heading will be displayed) |
|
|
Click to move the currently selected heading down the list (changing the order the heading will be displayed) |
|
|
Displays a sub window allowing a selection of pre-defined Headings. |
|
|
Save a constructed heading for later selection in the Standard Headings list. |
Note:
Creating a Question has the result of creating a SELEC element within the database.
To change a Question type; highlight a row in the Questions table and select a new value from the Question drop-down to the right of the table. The available Question types are as follows:
|
Angle |
Stype |
Bolt Diameter |
|
Pbore |
Type |
Bolt Type |
|
Pconn |
Radius |
Bolt Select |
|
Pressure |
Rating |
|
|
Shop |
Temperature |
When dealing with a PBORE, a Qualifier can be either a null value or a numeric value from 0 – 9, change the value by selecting a value from the Qualifier drop-down to the far right of the window.
Each Question column must have a default value set to either a definite answer (a value, word, etc) or to a – or = character. TYPE, NAME and PBOR columns must have – (null) defaults values and the Reference Pointer columns must have no default entries at all.
Click Save Headings to commit changes.
Click Back to return to the Tasks sub window.
Click Use Standard Heading Sets to display the Add Standard Headings sub window:

From the Add Standard Headings sub window, it is possible to pick from pre-defined headings.
The selections available in the list depends on whether you are editing an existing spec, or creating a new one, as the left hand list will contain the list of questions available from the spec.
The Standard Headings list contains a list of stored questions.
Upon selection of the required Standard Heading the right hand Questions and Defaults list will be populated with appropriate questions.
Note:
The list of available Standard Headings is maintained in the standard-headings file
located in PMLUI>cats>dflts. The location of the PMLUI folder may vary depending on
installation.
Click Use Standard Headings to commit changes.
Click Back to return to the Tasks sub window.