Hanger Templates
- Last UpdatedJan 13, 2023
- 7 minute read
To use the standard hanger templates, the default option property for the MDSHANGIF keyword must be set to Standard MDS in the AVEVA Catalog defaults database. Refer to Project Hanger Interface (MDSHANGIF) for further information.
The standards are available in the Supports application. The list varies slightly depending on the manufacturer selected for the hanger components. For example, Platforms Stairs and Ladders (PSL), GRINNELL (now ANVIL) and PIHASA. The sample set of templates for PSL is listed.
The standards marked with a * are not available in the Supports application. These standards are obsolete and have been replaced by other new standards.
|
Standard Name |
Replacement Name |
Default Description |
|---|---|---|
|
FH01 |
FH T1 M1 B1 |
Fixed Hanger NPS 3/4 - 6. |
|
FH02 |
FH T1 M1 B2 |
Fixed Hanger NPS 8 - 24. |
|
FH03 |
FH T1 M1 B5 |
Fixed Hanger NPS 1/2 - 2. |
|
FH04 |
FH T1 M1 B6 |
Fixed Hanger NPS 3 - 24. |
|
FH05 |
FH T1 M2 B1 |
Fixed Hanger NPS 3/4 - 6. |
|
FH06 |
FH T1 M2 B2 |
Fixed Hanger NPS 8 - 24. |
|
FH07 |
FH T1 M2 B5 |
Fixed Hanger NPS 1/2 - 2. |
|
FH08 |
FH T1 M2 B6 |
Fixed Hanger NPS 3 - 24. |
|
FH09 |
FH T3 M2 B1 |
Fixed Hanger NPS 3/4 - 6. |
|
FH10 |
FH T3 M2 B2 |
Fixed Hanger NPS 8 - 24. |
|
FH11 |
FH T3 M2 B5 |
Fixed Hanger NPS 1/2 - 2. |
|
FH12 |
FH T3 M2 B6 |
Fixed Hanger NPS 3 - 24. |
|
FH13* |
FH T1 M1 B7 |
Fixed Hanger NPS 2 - 18. |
|
FH13 |
FH T1 M1 B9 |
Fixed Hanger NPS 2 - 18. |
|
FH14* |
FH T1 M2 B7 |
Fixed Hanger NPS 2 - 18. |
|
FH14 |
FH T1 M2 B9 |
Fixed Hanger NPS 2 - 18. |
|
FH15 |
FH T4 M1 B1 |
Fixed Hanger NPS 3/4 - 6. |
|
FH16 |
FH T4 M1 B2 |
Fixed Hanger NPS 8 - 24. |
|
FH17 |
FH T4 M1 B5 |
Fixed Hanger NPS 1/2 - 2. |
|
FH18 |
FH T4 M1 B6 |
Fixed Hanger NPS 3 - 24. |
|
FH19 |
FH T4 M2 B1 |
Fixed Hanger NPS 3/4 - 6. |
|
FH20 |
FH T4 M2 B2 |
Fixed Hanger NPS 8 - 24. |
|
FH21 |
FH T4 M2 B5 |
Fixed Hanger NPS 1/2 - 2. |
|
FH22 |
FH T4 M2 B6 |
Fixed Hanger NPS 3 - 24. |
|
FH23 |
FH T1 M1 B8 |
Fixed Hanger NPS 3 - 24. |
|
FH24 |
FH T1 M2 B8 |
Fixed Hanger NPS 3 - 24. |
|
FH25 |
FH T3 M2 B8 |
Fixed Hanger NPS 3 - 24. |
|
FH26 |
FH T4 M1 B8 |
Fixed Hanger NPS 3 - 24. |
|
FH27 |
FH T4 M2 B8 |
Fixed Hanger NPS 3 - 24. |
|
FH28 |
FH T1 M1 B10 |
Fixed Hanger NPS 6 - 24. |
|
FH29 |
FH T1 M2 B10 |
Fixed Hanger NPS 6 - 24. |
|
FH30 |
FH T3 M2 B10 |
Fixed Hanger NPS 6 - 24. |
|
FH31* |
FH T3 M2 B7 |
Fixed Hanger NPS 2 - 18. |
|
FH31 |
FH T3 M2 B9 |
Fixed Hanger NPS 2 - 18. |
|
FH51 |
FH T3 B1 |
Fixed Hanger NPS 3/4 - 6. |
|
FH52 |
FH T3 B2 |
Fixed Hanger NPS 8 - 24. |
|
FH53 |
FH T3 B5 |
Fixed Hanger NPS 1/2 - 2. |
|
FH54 |
FH T3 B6 |
Fixed Hanger NPS 3 - 24. |
|
FH55* |
FH T3 B7 |
Fixed Hanger NPS 2 - 18. |
|
FH55 |
FH T3 B9 |
Fixed Hanger NPS 2 - 18. |
|
FH56 |
FH T3 B8 |
Fixed Hanger NPS 3 - 24. |
|
FH57 |
FH T3 B10 |
Fixed Hanger NPS 6 - 24. |
|
FH58* |
FH T4 M1 B7 |
Fixed Hanger NPS 2 - 18. |
|
FH58 |
FH T4 M1 B9 |
Fixed Hanger NPS 2 - 18. |
|
FH59 |
FH T4 M1 B10 |
Fixed Hanger NPS 6 - 24. |
|
FH60 |
FH T4 M2 B10 |
Fixed Hanger NPS 6 - 24. |
|
FH61* |
FH T4 M2 B7 |
Fixed Hanger NPS 2 - 18. |
|
FH61 |
FH T4 M2 B9 |
Fixed Hanger NPS 2 - 18. |
|
VH01 |
VH T1 M3 B1 |
Variable Hanger NPS 3/4 - 6. |
|
VH02 |
VH T1 M3 B2 |
Variable Hanger NPS 8 - 24. |
|
VH03 |
VH T1 M3 B5 |
Variable Hanger NPS 1/2 - 2. |
|
VH04 |
VH T1 M3 B6 |
Variable Hanger NPS 3 - 24. |
|
VH05 |
VH T3 M3 B1 |
Variable Hanger NPS 3/4 - 6. |
|
VH06 |
VH T3 M3 B2 |
Variable Hanger NPS 8 - 24. |
|
VH07 |
VH T3 M3 B5 |
Variable Hanger NPS 1/2 - 2. |
|
VH08 |
VH T3 M3 B6 |
Variable Hanger NPS 3 - 24. |
|
VH09 |
VH T9 M1 B1 |
Variable Hanger NPS 3/4 - 6. |
|
VH10 |
VH T9 M1 B2 |
Variable Hanger NPS 8 - 24. |
|
VH11 |
VH T9 M1 B5 |
Variable Hanger NPS 1/2 - 2. |
|
VH12 |
VH T9 M1 B6 |
Variable Hanger NPS 3 - 24. |
|
VH13 |
VH T9 M2 B1 |
Variable Hanger NPS 3/4 - 6. |
|
VH14 |
VH T9 M2 B2 |
Variable Hanger NPS 8 - 24. |
|
VH15 |
VH T9 M2 B5 |
Variable Hanger NPS 1/2 - 2. |
|
VH16 |
VH T9 M2 B6 |
Variable Hanger NPS 3 - 24. |
|
VH17 |
VH T10 M1 B1 |
Variable Hanger NPS 3/4 - 6. |
|
VH18 |
VH T10 M1 B2 |
Variable Hanger NPS 8 - 24. |
|
VH19 |
VH T10 M1 B5 |
Variable Hanger NPS 1/2 - 2. |
|
VH20 |
VH T10 M1 B6 |
Variable Hanger NPS 3 - 24. |
|
VH21 |
VH T10 M2 B1 |
Variable Hanger NPS 3/4 - 6. |
|
VH22 |
VH T10 M2 B2 |
Variable Hanger NPS 8 - 24. |
|
VH23 |
VH T10 M2 B5 |
Variable Hanger NPS 1/2 - 2. |
|
VH24 |
VH T10 M2 B6 |
Variable Hanger NPS 3 - 24. |
|
VH25* |
VH T1 M3 B7 |
Variable Hanger NPS 2 - 18. |
|
VH25 |
VH T1 M3 B9 |
Variable Hanger NPS 2 - 18. |
|
VH26 |
VH T3 M2 B14 |
Variable Hanger NPS 3 - 24. |
|
VH27* |
VH T3 M3 B7 |
Variable Hanger NPS 2 - 18. |
|
VH27 |
VH T3 M3 B9 |
Variable Hanger NPS 2 - 18. |
|
VH28* |
VH T9 M1 B7 |
Variable Hanger NPS 2 - 18. |
|
VH28 |
VH T9 M1 B9 |
Variable Hanger NPS 2 - 18. |
|
VH29* |
VH T9 M2 B7 |
Variable Hanger NPS 2 - 18. |
|
VH29 |
VH T9 M2 B9 |
Variable Hanger NPS 2 - 18. |
|
VH30* |
VH T10 M1 B7 |
Variable Hanger NPS 2 - 18. |
|
VH30 |
VH T10 M1 B9 |
Variable Hanger NPS 2 - 18. |
|
VH31* |
VH T10 M2 B7 |
Variable Hanger NPS 2 - 18. |
|
VH31 |
VH T10 M2 B9 |
Variable Hanger NPS 2 - 18. |
|
VH32 |
VH T4 M3 B1 |
Variable Hanger NPS 3/4 - 6. |
|
VH33 |
VH T4 M3 B2 |
Variable Hanger NPS 8 - 24. |
|
VH34 |
VH T4 M3 B5 |
Variable Hanger NPS 1/2 - 2. |
|
VH35 |
VH T4 M3 B6 |
Variable Hanger NPS 3 - 24. |
|
VH36 |
VH T13 M1 B1 |
Variable Hanger NPS 3/4 - 6. |
|
VH37 |
VH T13 M1 B2 |
Variable Hanger NPS 8 - 24. |
|
VH38 |
VH T13 M1 B5 |
Variable Hanger NPS 1/2 - 2. |
|
VH39 |
VH T13 M1 B6 |
Variable Hanger NPS 3 - 24. |
|
VH40 |
VH T13 M2 B1 |
Variable Hanger NPS 3/4 - 6. |
|
VH41 |
VH T13 M2 B2 |
Variable Hanger NPS 8 - 24. |
|
VH42 |
VH T13 M2 B5 |
Variable Hanger NPS 1/2 - 2. |
|
VH43 |
VH T13 M2 B6 |
Variable Hanger NPS 3 - 24. |
|
VH44 |
VH T14 M1 B1 |
Variable Hanger NPS 3/4 - 6. |
|
VH45 |
VH T14 M1 B2 |
Variable Hanger NPS 8 - 24. |
|
VH46 |
VH T14 M1 B5 |
Variable Hanger NPS 1/2 - 2. |
|
VH47 |
VH T14 M1 B6 |
Variable Hanger NPS 3 - 24. |
|
VH52 |
VH T1 M3 B8 |
Variable Hanger NPS 3 - 24. |
|
VH53 |
VH T3 M3 B8 |
Variable Hanger NPS 3 - 24. |
|
VH54 |
VH T4 M3 B8 |
Variable Hanger NPS 3 - 24. |
|
VH55 |
VH T9 M1 B8 |
Variable Hanger NPS 3 - 24. |
|
VH56 |
VH T9 M2 B8 |
Variable Hanger NPS 3 - 24. |
|
VH57 |
VH T10 M1 B8 |
Variable Hanger NPS 3 - 24. |
|
VH58 |
VH T10 M2 B8 |
Variable Hanger NPS 3 - 24. |
|
VH59 |
VH T13 M1 B8 |
Variable Hanger NPS 3 - 24. |
|
VH60 |
VH T13 M2 B8 |
Variable Hanger NPS 3 - 24. |
|
VH61 |
VH B15 |
Variable Pedestal NPS 3 - 24. |
|
VH62 |
VH B16 |
Variable Pedestal NPS 3 - 24. |
|
VH63 |
VH T1 M1 B13 |
Variable Hanger NPS 3 - 24. |
|
VH64 |
VH T1 M2 B13 |
Variable Hanger NPS 3 - 24. |
|
VH65 |
VH T3 M2 B13 |
Variable Hanger NPS 3 - 24. |
|
VH66 |
VH T4 M1 B13 |
Variable Hanger NPS 3 - 24. |
|
VH67 |
VH T4 M2 B13 |
Variable Hanger NPS 3 - 24. |
|
VH68 |
VH T1 M3 B10 |
Variable Hanger NPS 6 - 24. |
|
VH69 |
VH T3 M3 B10 |
Variable Hanger NPS 6 - 24. |
|
VH70 |
VH T4 M3 B10 |
Variable Hanger NPS 6 - 24. |
|
VH71 |
VH B17 |
Variable Pedestal NPS 3 - 24. |
|
VH80 |
VH T1 M3 B11 |
Variable Hanger NPS 3 - 24. |
|
VH81 |
VH T3 M3 B11 |
Variable Hanger NPS 3 - 24. |
|
VH82 |
VH T4 M3 B11 |
Variable Hanger NPS 3 - 24. |
|
VH83 |
VH T9 M1 B11 |
Variable Hanger NPS 3 - 24. |
|
VH84 |
VH T9 M2 B11 |
Variable Hanger NPS 3 - 24. |
|
VH85 |
VH T10 M1 B11 |
Variable Hanger NPS 3 - 24. |
|
VH86 |
VH T10 M2 B11 |
Variable Hanger NPS 3 - 24. |
|
VH87 |
VH T13 M1 B11 |
Variable Hanger NPS 3 - 24. |
|
VH88 |
VH T13 M2 B11 |
Variable Hanger NPS 3 - 24. |
|
VH89 |
VH T14 M1 B11 |
Variable Hanger NPS 3 - 24. |
|
VH101 |
VH T3 B13 |
Variable Hanger NPS 3 - 24. |
|
VH102 |
VH T3 B14 |
Variable Hanger NPS 3 - 24. |
|
VH103 |
VH T1 M1 B14 |
Variable Hanger NPS 3 - 24. |
|
VH104 |
VH T4 M1 B14 |
Variable Hanger NPS 3 - 24. |
|
VH105 |
VH T9 M1 B10 |
Variable Hanger NPS 6 - 24. |
|
VH106 |
VH T10 M1 B10 |
Variable Hanger NPS 6 - 24. |
|
VH107 |
VH T13 M1 B10 |
Variable Hanger NPS 6 - 24. |
|
VH108 |
VH T14 M1 B10 |
Variable Hanger NPS 6 - 24. |
|
VH109* |
VH T13 M1 B7 |
Variable Hanger NPS 2 - 18. |
|
VH109 |
VH T13 M1 B9 |
Variable Hanger NPS 2 - 18. |
|
VH110* |
VH T14 M1 B7 |
Variable Hanger NPS 2 - 18. |
|
VH110 |
VH T14 M1 B9 |
Variable Hanger NPS 2 - 18. |
|
VH111* |
VH T14 M1 B8 |
Variable Hanger NPS 3 - 24. |
|
VH113 |
VH T9 M2 B10 |
Variable Hanger NPS 6 - 24. |
|
VH114 |
VH T10 M2 B10 |
Variable Hanger NPS 6 - 24. |
|
VH115 |
VH T13 M2 B10 |
Variable Hanger NPS 6 - 24. |
|
VH117* |
VH T13 M2 B7 |
Variable Hanger NPS 2 - 18. |
|
VH117 |
VH T13 M2 B9 |
Variable Hanger NPS 2 - 18. |
|
VH118 |
VH T4 M2 B14 |
Variable Hanger NPS 3 - 24. |
|
VH120 |
VH T1 M2 B14 |
Variable Hanger NPS 3 - 24. |
|
VH121* |
VH T4 M3 B7 |
Variable Hanger NPS 2 - 18. |
|
VH121 |
VH T4 M3 B9 |
Variable Hanger NPS 2 - 18. |