Cableway Data
- Last UpdatedJan 23, 2023
- 1 minute read
Use to define the default Width and Height for the cableway volume (which includes the space for the cables volume and material) the access height default, maximum layers default, Cable Excess (excess length default) as a percentage of the total length of the cable.
Use to specify the Maximum Fill default (based on the cross-sectional area of the cableway volume) and Fill Check Utility Allowance default based on the cross-sectional area of the cableway volume (the value must be greater than 1).
Note:
Maximum fill can no longer be input at values greater than 100%.
Click to select the Allowable Class:
-
unset - default
-
POWER
-
COMMS
-
SIGNAL
-
CONTROL
-
WIRE
Click the Create Head/Tail RNODEs checkbox to automatically create the head/tail RNODEs on the ends of the cableway branch.
The Purpose field is automatically populated with the CABL attribute by default.