Position and Orientation Status Flags
- Last UpdatedFeb 19, 2025
- 1 minute read
Keywords
ORIFLAG POSFLAG
Description
These attributes are automatically set to TRUE when the Component is positioned and orientated. They are used by Model in several situations where it requires to know if a Component has been properly positioned.
Examples |
|
|---|---|
|
POSF FALSE |
This setting will occur if the Components have been transferred from a P&ID and not positioned. The Component will not be drawn in the views. |
|
ORIF FALSE POSF TRUE |
This setting will occur if the item has been Selected in Model but not oriented. |
|
ORIF TRUE POSF TRUE |
After the Component is oriented it will be shown in normal line type. |
Note:
If either POSFLAG or ORIFLAG remains FALSE, the next Component cannot be positioned
using ordinary routing commands.
Command Syntax
These attributes are set automatically by MODEL when positioning and orientation takes place. However, they can be set explicitly as follows:
>--+-- ORIFlag --.
| |
‘-- POSFlag --+-- TRue ---.
| |
‘-- FALse --+-->
Querying
>-- Query --+-- POSFlag --.
| |
‘-- ORIFlag --+-->