Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

Plates

  • Last UpdatedJan 23, 2023
  • 1 minute read

PLATE <ID> <state> <point> <height> <material> <pos> <ori> <vertexCount> <changedVertex>

The rules for values in each of the above fields are as for the Linear Members.

Note that holes themselves are not compared. This is principally because the transfer is incomplete anyway. The interface only transfers PLOO and NXTR based penetrations. No other negative primitives can be transferred at the moment.

Below is a sample portion of log file in brief format following an Import:

All profiles were mapped

The following profiles were not in the specified standards

HP200x54 has 1 occurrences

All mapped profiles were in the default standard

======================================

LINMEM =15322/447 C Y   N   Y N N N

LINMEM =15322/448 C Y   N   Y N N N

LINMEM =15322/449 C N   N   Y N N N

LINMEM =15322/450 C Y   N   Y N N N

LINMEM =15322/451 C Y N N   Y N N N

PLATE =15322/1015 C N   N N N Y N Y

PLATE =15322/1104 C N   N N Y N N Y

PLATE =15322/296 C N   N N Y Y N Y

PLATE =15322/414 C N   N N Y Y N Y

PLATE =15322/598 C N   N N N Y N Y

PLATE =15322/722 C N   N N N Y N Y

LINMEM =15322/423 D N N N N N N N

LINMEM =15322/878 D N N N N N N N

PLATE =15322/553 D N   N N N N N N

Related Links