Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

ROW

  • Last UpdatedAug 13, 2025
  • 2 minute read

The symbolic templates for the row in this table are held in the following Label Libraries:

HVAC

/TT/Isometric_ADP/Hvac/MtoTable-Templates

Electrical CWAY

/TT/Isometric_ADP/Cway/MtoTable-Templates

Each cell is very similar in that the hash code used is the same. The #ATEX is used because IsoADP functionality calculates the value required using the associated PML Function and stores it in the resulting SLAB attribute ATEX.

The Label Libraries hold data about the function of the owned symbolic templates, the build direction and the entry spacing.

SpPurpose TABTEM

Indicates that the purpose of this Label Library is to hold Table Templates

Function 'Hvac Mto Table Template

The Table Templates are for HVAC Mto, the description must be exact.

Function 'Cway Mto Table Template

The Table Templates are for Electrical CWAY Mto, the description must be exact.

:IdpMove 4

The distance from one entry to the next in mm.

:IdpDire -Y

The table build direction.

The Label Library owns four SYTM elements that produces a table entry:

Apart from the single TEXP element that has the attribute BTEX set to #ATEX, the SYTM owns a series of STRA elements that represent the sides of the cell.

Each SYTM holds data about the cell that it represents, the data is held in a series of User Defined Attributes.

TitleResults for “How to create a CRG?”Also Available in