Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

Circular Air Intake Hood

  • Last UpdatedJan 24, 2023
  • 2 minute read

The task of creating an HVAC Component is initiated from the HVAC Window.

Select Extra Inline Equipment in the Categories drop-down list and then Circular Air Intake Hood in the Available Type drop-down list to display the Air Intake Hood window:

The Air Intake Hood window default is a standard stock size, but can be changed by you using one of the following methods:

Standard Stock Sizes

In the Name(Ref) field, input the name of the HVAC component.

Note:
The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalog.

To choose from the standard stock sizes available from the HVAC Catalog, in the Stock Size drop-down list, click the required size for the HVAC component.

Non Standard Stock Sizes (Special)

If you chose not to use a standard stock piece of HVAC, from the Stock Size drop-down list, click Special.

You are required to input the following dimensions:

  • Name(Ref)

  • Duct Diameter

  • Overall Diameter

  • Overall Height

  • Cowl Height

To visualize how the dimensions equate to the actual piece of HVAC, click Picture to display a detailed drawing for Circular Air Intake Hood.

Note:
The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalog.

Specify a type of joint to use for the Arrive Joint. Refer to Create/Modify HVAC Component for a detailed description.

In the Position list, select Connect or Unchanged:

  • Click Connect (default when Create is selected) - connects the piece of HVAC to the previous one.

  • Click Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.

    Note:
    Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.

Click Defaults to reset all the fields back to when the Air Intake Hood window was opened.

Click Fit to orientate the Air Intake Hood to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.

Click OK to create the Air Intake Hood component and close the Air Intake Hood Window. You will be returned to the HVAC Window.

Click Cancel to discard all the field changes and close the Air Intake Hood window.