Mesh End
- Last UpdatedJan 24, 2023
- 2 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
Select Circular in the Categories drop-down list and then Mesh End in the Available Type drop-down list to display the Circular Mesh End window:

You are required to input the following dimensions:
-
Duct Diameter
-
Mesh X Spacings
-
Mesh Y Spacings
-
Mesh Wire Gauge
-
Graphical length
To visualize how the dimensions equate to the actual piece of HVAC, click Picture to display a detailed drawing for Mesh End.
Note:
The fields will be pre-populated with default dimension. These dimension are governed
by the details defined in the HVAC Catalog.
Specify a type of joint to use for the Arrive Joint. Refer to Create/Modify HVAC Component for a detailed description.
In the Position list, select Connect or Unchanged:
-
Click Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Click Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.
Note:
Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.
Click Defaults to reset all the fields back to when the Circular Mesh End window was opened.
Click Fit to orientate the Circular Mesh End to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
Click OK to create the Circular Mesh End component and close the Circular Mesh End Window. You will be returned to the HVAC Window.
Click Cancel to discard all field changes and close the Circular Mesh End window.