Suppressing Clash Repetition in Reports

  • Last UpdatedFeb 19, 2025
  • 1 minute read

Keywords

REPORT FIRST

Description

When used before an OUTPUT command, the REPORT FIRST option allows the user to generate a sequence of reports from a single set of clash data such that each clash is reported once only throughout the complete sequence.

Example

REPORT FIRST ALL

OUTPUT /ZONE.PIPES

OUTPUT /ZONE.STEELW

Assume a clash check has just been run which includes piping and steelwork items among the elements checked. Then this sequence generates two separate reports; the first (from OUTPUT /ZONE.PIPES) shows all clashes involving pipework elements, including those between pipework and steelwork; the second (from OUTPUT /ZONE.STEELW) shows all clashes involving steelwork elements except those which were included in the first report (i.e. the second report omits clashes between pipework and steelwork.

Command Syntax

>--- REPort FIRst ALL --->