Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

Component Visibility, Drawing Level and Obstruction

Component Visibility, Drawing Level and Obstruction

  • Last UpdatedJan 13, 2023
  • 2 minute read

2D and 3D geometry components have a number of attributes that control the representation in the graphics window. The most important of these attributes are:

Tubeflag

The Tubeflag attribute may be set to TRUE or FALSE (the default) and is effectively an ON/OFF flag for component visibility. For structural geometry components it is essential that Tubeflag is set to TRUE, i.e. ON.

Level

The Level attribute contains two numbers indicating the inclusive range of the drawing levels that the component will be displayed on, e.g. if a components Level attribute is set to 4 8, the component will be visible on drawing levels 4 through 8 inclusive in the graphics window.

For SPRF components it is usual to create three geometry definitions with the appropriate components on different drawing levels, for example:

Simplified: Level 0 – 4 Obstruction value 0

This representation is used in Draft if an isometric view of the profile is required.

Actual: Level 5 – 8 Obstruction value 2

This representation is used for most 3D and 2D graphics as it is the true representation of the profile.

Obstruction: Level 9 -10 Obstruction value 1

This representation is used for the obstruction volumes of the profile.

Obstruction

The Obstruction attribute informs the clash detection facility whether a geometry component should be considered as:

Hard

Obstruction value of 2

Soft

Obstruction value of 1

None

Obstruction value of 0

The SANN, SREC and SPRO creation sub forms have a Representation option that enables pre-set values for Level, Obstruction and Tubeflag to be set. The following table gives the details of the Representation available:

Representation

Level

Obstruction

Tube flag

Default

0-10

2

FALSE

Profile Obstruction

3-5

2

TRUE

Profile Detail

6-8

0

TRUE

Profile Centerline

6-8

0

FALSE

Piping Obstruction

0-10

2

FALSE

Piping Reserved

0-10

1

FALSE

Piping Detail

0-10

2

TRUE

Piping Centreline

0-10

0

FALSE

Detail with No Obst

2-10

0

TRUE

Detail Volume

2-10

2

TRUE

Obstruction Volume

9-10

2

TRUE

Insulation Volume

7-10

1

TRUE

Reserved Volume

8-10

1

TRUE

TitleResults for “How to create a CRG?”Also Available in