Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

Radiused Splitter

  • Last UpdatedJan 24, 2023
  • 2 minute read

The task of creating an HVAC Component is initiated from the HVAC Window.

Select Rectangular in the Categories drop-down list and then Radiused Splitter in the Available Type drop-down list to display the Radiused Splitter window:

You are required to input dimensions for the new HVAC Component:

  • Duct Width AA

  • Duct Depth AB

  • Angle

  • Bend Inside Radius

  • Bend Arrive Extension

  • Bend Leave Extension

  • Splitter Radius

  • Splitter Arrive Extension

  • Splitter Leave Extension

To visualize how the dimensions equate to the actual piece of HVAC click Picture to display a detailed drawing for Radius Splitter.

Note:
The fields will be pre-populated dimensions. These dimensions are governed by the detailed defined in the HVAC Catalog.

Click Transpose Width/Depth to exchange Duct Width AA dimension with Duct Depth AB dimension.

In the Position list, select Connect or Unchanged:

  • Click Connect (default when create is selected) - connects the piece of HVAC to the previous one.

  • Click Unchanged (default when modify is selected) - positions the component at the co-ordinates 0.00.

Click Defaults to clear all the dimension currently in the window and set them to the dimension when the window was first opened.

Click Fit to orientate the piece of HVAC to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.

Click OK to create the Rectangular Radiused Splitter element in the Design database and close the Radiused Splitter Window. You will be returned to the HVAC Window.

Click Cancel to close the Radiused Splitter window and discard any dimension input in the fields.