Graphical Labelling of Design Elements

  • Last UpdatedFeb 19, 2025
  • 1 minute read

Keywords

MARK UNMARK

Description

This facility allows specific design elements or lengths of Tube to be labelled in the display.

Frequently referenced items may be marked with a constant graphic label which will stay with that item even if it is moved or rescaled. Items can also be unmarked (which removes the label).

Labels are shown in all permitted regions where the item’s origin is within the current sub-view. The label always points to the origin or, in the case of a Branch or Hanger, to its Head or Tail (where the name will be suffixed with + or ‑ respectively).

The user can specify selection criteria for marking, and specify any textual expression for the marker.

Examples

MARK /DATUM5

Element /DATUM5 will be labelled with its name.

UNMARK /DATUM5

The specified element will cease to be labelled.

MARK WITH ’Outer Boundary’ ID @

Labels the picked element with the given text.

MARK WITH (NAME) ALL BRAN

Labels all Branches with their AVEVA E3D Design names.

MARK WITH (NAME OF SPREF) WHERE ABORE GT 100

Labels all valves larger than the specified bore with their specification references in the Catalog.

UNMARK ALL

Removes all marking from the screen.

Command Syntax

>-- MArk --+-- WITH -- text expression --.

           |                             |

           ‘-----------------------------+-- <selatt> -->

>-- UNMark -- <selatt> -->

In This Topic
Related Links
TitleResults for “How to create a CRG?”Also Available in