Nominal Bores

  • Last UpdatedJan 13, 2023
  • 2 minute read

Select a list of bore sizes to match those in the specification from the Available Nominal Bores list.

Click to highlight the desired bore sizes in the Available Nominal Bores (mm) list. Multiple bores can be selected at once by left clicking and dragging the mouse pointer. To remove particular highlighted entries hold down the CTRL key and left click on a bore size.

Click Add > to populate the Nominal Bores column, to add the complete bore list to the Nominal Bore column, click Add All >>.

After adding the required Bores the Remove and Remove All options become active allowing the user to remove Bores from the Nominal Bores list.

Once the nominal bores column has been populated, add values to the Wall Thickness, Corrosion Allowance and Flange Allowances columns.

Wall Thickness Ref.

A reference to an existing wall thickness table, refer to Wall Thickness Reference for further information.

Corrosion Allowance

A numeric value to represent the corrosion allowance at that bore, refer to Corrosion Allowance for further information.

Flange Allowance

A numeric value or expression for setting extra tube lengths for flared or loose flanges, refer to Flange Allowance for further information.