Configuration of Hole Management Data
- Last UpdatedAug 14, 2025
- 1 minute read
Additional hole size properties on piping and HVAC components are used to control automatic hole dimensions. If these properties are not provided the system uses Hole Management default sizes (for example OD for pipe holes).
The following properties are used to control automatic hole sizes.
|
Property Name (DKEY) |
Description |
|---|---|
|
AHDI |
Property specifying the diameter of the hole required for the component, this is a REAL DISTANCE expression returning the hole diameter. The property is used if:
If the AHDI property is applied, the Clearance value is ignored. If the AHDI property is not applied, then the pipe OD + Clearance is used to calculate the hole size. |
|
AHX |
Property specifying the X dimension of a rectangular hole required for the component, this is a REAL DISTANCE expression. The property is used if it is associated with a HVAC component that clashes with the structural panel at the penetration. If the AHX property is applied, the Clearance value is ignored. If the AHX property is not applied, then the component width + Clearance is used to calculate the hole size. |
|
AHY |
As for AHX, but specifies the Y or height dimension of the hole. |