Joints for Rectangular Components Only

  • Last UpdatedJan 24, 2023
  • 1 minute read

RE25

Raw edge, longitudinal seam notched back 25 (1")

RE40

Raw edge, longitudinal seam notched back 40 (11/2")

RE50

Raw edge, longitudinal seam notched back 50 (2")

DM30

Ductmate™ 30mm (11/8") flange

DM40

Ductmate™ 40mm (11/2") flange

IDC

Integral duct connector

IDF

Integral duct flange

VM20

Verromez™ 20mm (3/4") flange

VM30

Verromez™ 30mm (11/8") flange

VM40

Verromez™ 40mm (11/2") flange

FLAT

For spigot plates only

A PML object HVACJOINTS is the only place that controls the HVAC Joint storage location.

method .hvcJoints()

-- Set defaults for the object members

if (!!cdHVACunits eq 'MM') then

!this.rectangularJointsStorage

= object DBREF('/CADCHVACCATA-Joints-RECT ')

!this.circularJointsStorage

= object DBREF('/CADCHVACCATA-Joints-CIRC ')

!this.flatOvalJointsStorage

= object DBREF('/CADCHVACCATA-Joints-FOVA ')

otherwise:

!this.rectangularJointsStorage

= object DBREF('/CADCHVACCATA-Joints-RECT-Imp ')

!this.circularJointsStorage

= object DBREF('/CADCHVACCATA-Joints-CIRC-Imp ')

!this.flatOvalJointsStorage

= object DBREF('/CADCHVACCATA-Joints-FOVA-Imp ')

endif

endmethod