Positioning of Sub-components
- Last UpdatedJan 23, 2023
- 1 minute read
To facilitate the positioning of sub-components on the faces of cataloged elements additional P-lines are required on profiles for beams, columns and walls. One P-line is required to define each face of the element.
The followings attributes should be set:
-
CCON attribute set to FACE or FACD - depending on whether the face is clockwise or anticlockwise from the edge.
-
PURP attribute should be the DKEY of the DATA element that represents the dimension perpendicular to the direction of the pline.
-
The LEVEL of these plines should be 10 to 11.
-
If the PKEY begins with an F the user can easily distinguish it from other p-lines.
-
The PLAXIS of the p-line should be perpendicular to the face.