Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

Positioning of Sub-components

  • Last UpdatedJan 23, 2023
  • 1 minute read

To facilitate the positioning of sub-components on the faces of cataloged elements additional P-lines are required on profiles for beams, columns and walls. One P-line is required to define each face of the element.

The followings attributes should be set:

  • CCON attribute set to FACE or FACD - depending on whether the face is clockwise or anticlockwise from the edge.

  • PURP attribute should be the DKEY of the DATA element that represents the dimension perpendicular to the direction of the pline.

  • The LEVEL of these plines should be 10 to 11.

  • If the PKEY begins with an F the user can easily distinguish it from other p-lines.

  • The PLAXIS of the p-line should be perpendicular to the face.