The geometry sets are created in project MDU. The examples display what is added and details any properties that are used. You can add geometry using the properties if required and add additional properties as necessary.

AT500 to AT700, BT500 to BT700, LT500 to LT700

Simple Box Representation

The box is set to a length of 10, and uses the pipe Outside Diameter (OD) as the X and Y length.

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1. All other design parameters are set to 0 (zero), as indicated in the Properties window.

No user editable design parameters have been defined.

AN500 to AN569

Anchor for Shoes

Simple Anchor Representation

These user standards ask for a pipe shoe to be identified so it can read the shoe parameters Shoe Height and Flange Width in order to size the anchor. It then asks for a section or box to be identified to read the anchor width across the section of box.

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1, 100, 102 and 133.2. All other design parameters are set to 0 (zero), as indicated in the Properties window.

Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added.

AN570 to AN639

Anchor for Pipes

Simple Box Representation

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1. All other design parameters are set to 0 (zero), as indicated in the Properties window.

No user editable design parameters have been defined.

GT500 to GT569

Guide for Shoes

Simple Guide Representation

These user standards ask for a pipe shoe to be identified so it can read the shoe parameters Shoe Height and Flange Width in order to size the guide.

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1, 100 and 102. All other design parameters are set to 0 (zero), as indicated in the Properties window.

Design parameters 1, 2, 3 and 4 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added.

GT570 to GT639

Guide for Pipes

Simple Guide Representation

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1 and 0. All other design parameters are set to 0 (zero), as indicated in the Properties window.

ST500 to ST569

Stop for Shoes

Simple Stop Representation

These user standards ask for a pipe shoe to be identified so it can read the shoe parameters Shoe Height and Flange Width in order to size the Anchor. It then asks for a section or box to be identified to read the anchor width across the section of box.

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1, 100 102 and 133.2. All other design parameters are set to 0 (zero), as indicated in Properties window.

Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added.

ST570 to ST639

Stop for Pipes

Simple Box Representation

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1. All other design parameters are set to 0 (zero) as indicated in the Properties window.

AN640 to AN700

Anchor for Trunnions

Simple Anchor Representation

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset. The Plate Length, Plate Width and Plate Thickness are obtained from the identified Base Plate. All other design parameters are set to 0 (zero) as indicated in the Properties window.

Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added.

ST640 to ST700

Stop for Trunnions

Simple Stop Representation

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset. The Plate Length, Plate Width and Plate Thickness are obtained from the identified base plate. All other design parameters are set to 0 (zero) as indicated in the Properties window.

Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added.

GT640 to GT700

Guide for Trunnions

Simple Guide Representation

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset. The Plate Length, Plate Width and Plate Thickness are obtained from the identified base plate. All other design parameters are set to 0 (zero) as indicated in the Properties window.

Design parameters 1, 2 and 3 have been declared as user editable (with an allowable range of 0 to 1000) and default values have been added.

AC500 to AC599

Ancillary Component for Trunnions

Simple Ancillary Representation

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1. All other design parameters are set to 0 (zero), as indicated in the Properties window.

No user editable design parameters have been defined.

AC600 to AC700

Plate Component for Trunnions

Simple Plate Representation

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection Type and 25 design parameters have been created. The list displays the parameters that have been preset, for example, to -1. All other design parameters are set to 0 (zero), as indicated in the Properties window.

No user editable design parameters have been defined.

CA500 to CA700

Cable Tray Ancillaries

Simple Cable Tray Ancillary Representation

The three standard catalog parameters have been added, Nominal Bore, Outside Diameter and Connection type and 21 design parameters have been created. The design parameters are set to 0 (zero) as indicated in the Properties window. Cable ancillaries do not include Minimum/Maximum Insulation and Minimum/Maximum Temperature parameters. The Outside Diameter is always set to 0 (zero) for cable tray ancillaries.

In This Topic