Transfer Lap Joint Stub Ends

  • Last UpdatedJan 24, 2023
  • 2 minute read

Functionality is available to support the transfer of Lap Joint Stub End (LJSE) elements to Rohr2.

The LJSE and the associated flange are combined into a single FLA component to be transferred to Rohr2.

The example displays a set of LJSE with associated lapped flanges.

When the LJSE is transferred to Rohr2, instead of being transferred as two separate components, the LJSE and FLAN are transferred as a single FLA entry in the Rohr2 neutral file. For example:

Because the two components from AVEVA E3D Design are combined into a single component, some of the transferred data is derived from the LJSE and some of the data is derived from the FLAN.

The table indicates how the data is transferred to the single FLA entry in the neutral file and what element the data is derived from.

Attribute

Expression

E3D Element

More Info

Component Description

NAME

LJSE

Material Description

MTXX

LJSE

Weight of elements (kg)

GWEI

FLAN + LJSE

Weight is the LJSE weight and FLAN weight added together.

Wall Thickness ppoint

1 (mm)

pwallt(1)

LJSE

Wall Thickness ppoint

2 (mm)

pwallt(2)

LJSE

Wall Thickness ppoint

3 (mm)

pwallt(3)

LJSE

Wall Thickness ppoint

4 (mm)

pwallt(4)

LJSE

Wall Thickness Outside Tolerance (%)

LJSE

Wall Thickness Inside Tolerance (%)

LJSE

Norm / Standard

FLAN

NORM obtained from the flange.

BTK

FLAN

The bolt thickness is taken from the flange.