Engineer Check

  • Last UpdatedJan 24, 2023
  • 1 minute read

Step 4

Click Check All in Output List. The result should be all checks have passed.

Click Set Section Types to scan the hierarchy and set the GENSEC Purpose attribute to the correct section type.

Set Section Types sets the Purpose attribute of vertical GENSECs to COLU, horizontal GENSECs to BEAM, and oblique GENSECs to BRAC. GENSECs with an angle in the horizontal direction with a value less than the input box are also set to BEAM.

The interface reads the Purpose attribute of the Hierarchy list to assess the GENSEC type.