You can Create, Edit, Save and Load various representation rules, to be applied to various element types.

Rules can be set from the Representation Settings pane:

Gtype

Select the Gtype element (Generic type) from the drop-down menu.

Rule Expression

Enter a Rule Expression in the text box (for example bore gt 80mm), if required.

Tube

Select Tube check box to display double line representation of piping components.

Centreline

Select Centreline check box to display single line representation of piping components.

Insulation

If selected, Insulation is displayed on the piping components and tubing, as defined in the catalog. Click on the drop-down menu to specify a level of translucency between 0% (Off) and 100% (Solid).

Obstruction

If selected, Obstruction volumes are displayed, as defined in the catalog (but only if the drawing level is set appropriately). Click on the drop-down menu to specify a level of translucency between 0% (Off) and 100% (Solid).

Level

Enter the drawing Level for the relevant Gtype element. In each case, enter the required level (which must be in the range 1-99).

Arc Tolerance

Defines the tolerance within which arcs must be drawn. To change the tolerance, edit the number in the text box.

Add to End of List

Click Add to End of List to add the new representation rule to the Representation List.

Replace Selection

Click Replace Selection to replace an existing representation rule.

Once you have added or replaced a representation rule, click Apply to apply the rules to the graphical display.

To restore the display to the default settings, click Reset Display.

To save Representation Rules set, select File > Save or to load a created rule set select File > Load.

Once you have completed configuring the Representation settings, click Apply to apply the settings. Click Dismiss to discard any changes made.

Click Load or Save, to load from and save to the options files stored at %AVEVA_DESIGN_USER%.