Specification to Limit Panel Thickness
- Last UpdatedFeb 11, 2025
- 1 minute read
Panel thickness availability in the Model module can be controlled via the catalogue Specification mechanism. Using ‘Ans’ ‘Maxans’ attributes on the SPCO can limit the allowable minimum and maximum panel thicknesses.
Note:
The CATREF is not used as the geometry is defined in the Model module.

|
Type |
Attribute |
Data |
Description |
|---|---|---|---|
|
SPEC |
Description |
{ str } |
display on form spec gadget |
|
Question |
THK |
question for offspring |
|
|
Purpose |
PLT |
spec purpose |
|
|
Tquestions |
thickness |
specific question for offspring |
|
|
SPCO |
Ans |
real |
min thickness |
|
Maxans |
real |
max thickness |