Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ E3D Design

Offline/Straight-Through Component Attribute

  • Last UpdatedFeb 19, 2025
  • 1 minute read

Keywords

LOFF

Description

This attribute controls whether a Component is considered to be ‘in-line’ or ‘off-line’. If it is off-line, the reporting utility will treat it as a continuous part of the Tube either side of the Component and will only report one pipe length. This is useful for BENDS (bends in continuous Tube) and OLETS (which tap off the side of a piece of Tube). If the Component is left as in-line, the Tube will be split into two sections with no account being taken of the Arrive-to-Leave length of the Component.

Examples

LOFF FALSE

In the reporting utility, the current element will be treated as a full Component which breaks the Tube lengths either side.

OFFL TRUE

In the reporting utility, the current element will be included as part of a single Tube length running through its Arrive-to-Leave centerline.

Note:
The default setting for this attribute is dependent upon Component type.

Command Syntax

>--+-- LOFFline --.
   |              |
   ‘-- OFFLine ---+-- TRue ---.
                  |           |
                  ‘-- FALse --+-->