Model Invalid Reference Check
- Last UpdatedJan 23, 2023
- 2 minute read
Checks that objects associated with the model have a valid reference. Objects with non-intelligent positions are always considered valid.
To use the facility, select the adjacent Primitives, Labels and/or Dimensions toggle options as required to specify the types of objects in the drawing to be checked, then click Model Invalid Ref. Check.
Objects with an intelligent position where the reference is unset or not valid are highlighted as invalid (red).
Objects with an intelligent position where the reference is valid are highlighted as valid (green).
Objects with non-intelligent positions (for example, 2D sheet or 3D world positions) are highlighted as valid (green).
Note:
The DDNM on labels with non-intelligent positions is not checked by this facility.

Click Model Invalid Ref. Check again to turn off checking. All objects display in their normal colors.
By default, a notification band is displayed at the top of the drawing canvas when model invalid reference check mode is active.

Note:
Model invalid reference check mode cannot be used if model reference check mode is
active.