  • 2 minute read

When the support structural member is attached to a stiffener the following calculations are used, where

SL =

Snipe length on the leg of the framework

FL =

Length of leg

M1 =

Control gap for back-to-back. The default is 10 mm.

M2 =

Length in the opposite direction of M1 on flange of stiffener

M3 =

Distance between flange top outside edge of stiffener and leg point connected with the flange top of stiffener (default = 25 mm)

When L > M1 + FL + M2 and M2 >= 25mm, Snip is not provided on support leg as below.

When L > M1 + FL + M2 and M2 < 25mm Snip is to be provided on support leg as below

When L =< M1 + FL and M2 (=M1 + FL - L) =< 0 (zero) mm Snip is to be provided on support leg as below