Example: Add a Bar above the HVAC

  • Last UpdatedJan 24, 2023
  • 1 minute read

In this case, relative positioning of the bar must be enabled as it is affected by any height changes to the duct. GENSEC start and end extensions are the same as bar 1.

The configuration is:

:MDSConfigA true,U,1,HEIGHT\true,0.5\true,0.5

Element Positioning

Enable Relative Element Positioning

Move Direction

Proportion of difference from Reference Duct

HVAC Relative Dimension

Value

TRUE

U

1

HEIGHT

Description

Relative positioning required.

Offsets are in the UP direction, relative to STRU orientation.

Bar is offset by 1 x (500 - HVAC dimension in relative direction, for example, HEIGHT).

The HVAC dimension that is compared against the reference.