Square Bend
- Last UpdatedJan 24, 2023
- 2 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
Select Rectangular in the Categories drop-down list and then Square Bend in the Available Type drop-down list to display the Square Bend window:

You are required to input the following dimensions:
-
Duct Width AA
-
Duct Depth AB
-
Duct Width LA
-
Arrive Throat
-
Leave Throat
-
Inside Radius
-
Back Radius
-
Arrive to Back Fillet
-
Leave to Back Fillet
-
Arrive Throat Fillet
-
Leave to Throat Fillet
-
Airturn Vanes
To visualize how the dimensions equate to the actual piece of HVAC, click Picture to display a detailed drawing for Square Bend.
Note:
The fields will be pre-populated with default dimension. These dimension are governed
by the details defined in the HVAC Catalog. The Airturns Vanes default is auto but can be changed by you to a required dimension.
Click Transpose Width/Depth to exchange Duct Width AA dimension with Duct depth AB dimension.
Specify a type of joint to use for the Arrive Joint and Leave Joint. Refer to Create/Modify HVAC Component for a detailed description.
After selecting the type of joint to use for the Arrive Joint and Leave Joint you must enter the Leave Direction.
In the Leave Direction specify the axis to be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).
In the Position list, select Connect or Unchanged:
-
Click Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Click Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.
Note:
Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.
Click Defaults to reset all the fields back to when the Square Bend was opened.
Click Fit to orientate the Square Bend to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
Click OK to create the Square Bend component and close the Square Bend Window. You will be returned to the HVAC Window.
Click Cancel to discard all field changes and close the Square Bend window.