Description

The PVOL command sets the list of penalty volumes which will be considered during the automatic routing process.

Example

PVOL /PV1

Adds /PV1 into the list of Penalty Volumes. If the element being added is not a PVOL, then all items below it in the hierarchy are scanned.

PV /PZONE1 /PZONE2

Adds /PZONE1 and /PZONE2 to the list. A maximum of 1000 PVOLS may be considered during automatic routing.

PV 

Clears the list of Penalty Volumes.

Command Syntax

                    .----<-----.
                   /           |
>-- PVolumes --+--*-- <sgid> --+-->
               |
               ‘-->