Two Bend Set-fill
- Last UpdatedJan 24, 2023
- 2 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
From the HVAC Window select Rectangular in the Categories drop-down list and then Two Bend Setfill in the Available Type drop-down list to display the Two Bend Set-fill window:

You are required to input the following dimensions:
-
Duct Width AA
-
Duct Depth AB
-
Inside Radius
-
1st Bend - Arrive Extension
-
1st Bend - Leave Extension
-
2nd Bend - Arrive Extension
-
2nd Bend - Leave Extension
To visualize how the dimensions equate to actual piece of HVAC click Picture to display a detailed drawing for Two Bend Setfill.
Note:
The fields will be pre-populated with default dimensions. These dimensions are governed
by the details defined in the HVAC Catalog. The Arrive and Leave Extension for the 1st and 2nd Bends default is auto but can
be changed by you to a required dimension.
Click Transpose Width/Depth to exchange Duct Width AA dimension with Duct Depth AB dimension.
Specify a type of joint to use for the Arrive Joint and Leave Joint for both the 1st and 2nd Bends. Refer to Create/Modify HVAC Component for a detailed description.
Click Defaults to reset all the fields back to when the Two Bend Setfill window.
Click OK to create the Two Bend Setfill component and close the Two Bend Setfill Window. You will be returned to the HVAC Window.
Click Cancel to discard all field changes and close the Two Bend Setfill window.