AVEVA™ E3D Design

Hanger Length Table

  • Last UpdatedFeb 11, 2025
  • 2 minute read

The Hanger Length Table is used by the application to determine the minimum and maximum Head to Tail lengths for a given configuration. This is checked every time a hanger is created, but it is most important for template-type configurations which use the minimum length to position the supporting members. The values derived from this table override the values set in the configuration CATE :MAXLEN and :MINLEN attributes.

The Hanger Length Table should be in a SPEC with PURP set to HMML. An example named /CADC/HS/SAMPLE/SPEC/HANGLEN is supplied with the product.

The following hierarchy is mandatory for the Hanger Length Table:

Specification (SPEC)

QUES

PBOR

:VISI

false

PURP

HMML

DESC

<optional text description>

1st Level of Selection (SELE)

ANS

<pipe nominal bore>

QUES

SMAT

2nd Level of SELE

TANS

<steel material code> *

QUES

PMAT

3rd Level of SELE

TANS

<pipe material code> *

QUES

HTYP

Specific Component (SPCO) level

ANS

<length type code> **

TANS

<hanger configuration type code> ***

COMM

<min length>/<max length> (including units, e.g. 0mm/60mm)

*

Material codes are defined in the application defaults from the Settings>Admin>Materials menu option.

**

This can be set to 0 or 1:

1 - Lengths are calculated from outside of pipe. This is the default mode if a configuration is not defined in the Hanger Length Table.

0 ‑ Lengths are calculated from the C/L of the pipe. In this mode, the application selects the PCLA to calculate the minimum length when creating support templates

***

Code corresponds to the Hanger Build Macro suffix and the Generic Type (GTYP) of the configuration Category (CATE).

Related Links