The following CAD formats are supported for import to POPMesh using the Hoops importer.

  • STEP

  • Navisworks (NWD)

  • DWG

  • IFC

  • REVIT

  • Solidworks files from 97 up to 2024

  • Rhino files from 4 to 7

  • JT (Jupiter Tessellation) files up to 10.9

  • GLTF (GL Transmission Format) files 2.0 only

  • IGES (Initial Graphics Exchange Specification) 5.1, 5.2, 5.3

Parameters

These are the settings for the import configuration file.

Parameter

Type

Default

Description

customSignificantFilePath

sstring

Not set

Config file path including extension. Use when useCustomSignificantFile is set to true.

destinationpath

sstring

 Not set

The source destination path. Include filename with extension to overwrite file name.

enforceUniqueTags

sbool

true

Collapse multiple same-tagged nodes into a single node with a unique tag.

increaseProcessPriority

sbool

false

Increase the Converter Process CPU priority.

keepConverterCache

sbool

true

Keep conversion cache in workDir for future use.

preserveModelUpVector

sbool

false

Preserve the up vector of the source model. This means don't convert it to Y-up, left-handed.

maxTrianglesPerBlock

sint

-1

Specify the max number of triangles for each block. If not specified, use the system default value.

useCacheForPreprocessFiles

sbool

true

Looks for available cache in workDir to use during preprocess.

useCustomSignificantFile

sbool

 false

Set to true to pass a config file or to directly use the userIncludeList and userExcludeList. Set to false to use default settings.

userExcludeList

sstring

Not set

Components that are excluded in the import process. Use when useConfigPath is set to true and no configPath is specified.

userIncludeList

sstring

Not set

Components that are included in the import process. Use when useConfigPath is set to true and no configPath is specified.

useLogAnalyzer

sstring

onFailAndOnSuccess

Enables process log analyzer tool on failure, or on failure followed by success. Valid values are: disabled, onFail, onFailAndOnSuccess.

wasmOutput

sbool

false

If true, the destination path is set to the wasm default datapath and the node creation is skipped.

workDir

sstring

 Not set

Specifies the directory to be used for conversion process. If keepConverterCache is set to true, this folder will persist conversion cache for possible future use.