AVEVA™ Mobile Operator

Search/Input Device

  • Last UpdatedFeb 07, 2025
  • 6 minute read

Use Search/Input Device settings to configure the peripheral devices.

To access Search/Input Device settings

  1. Tap the Menu button, and then tap Settings.

    The Settings screen appears.

  2. Tap Search/Input Device.

    The Search/Input Device screen appears.

To access settings of a peripheral device

  • On the peripheral device, tap the Next button.

    The peripheral device screen appears.

Configure Search/Input Device settings as follows:

Basic

Basic search/input device settings provide settings to configure capabilities and fields for a peripheral device.

Search is the capability to use a peripheral device during a search.

  • Tap to select Search to enable search capability for the peripheral device.

  • Tap to clear selected Search to disable search capability for the peripheral device.

Input

Input is the capability to use a peripheral device for populating a field.

  • Tap to select Input to enable input capability for the peripheral device.

  • Tap to clear selected Input to disable input capability for the peripheral device.

Default Supported Peripherals

The default value is based on the peripheral device, and is not available to configure if it is not supported by the peripheral device. The following peripherals are supported by default:

  • Camera

  • Land Cyclops

  • Raynger MX4 W/BT

  • TPI 9080/9085 Vibration Analyzer

  • NFC

  • Bartec RFID Pen

Device Instance

Device instance is the instance of a peripheral device as configured in the Device Registration module of the Management Center.

To select a device instance

  1. Tap the Device Instance list.

    The list of device instances screen appears.

  2. Tap to select a device instance.

    The device instance is selected, and the peripheral device screen appears.

    Search Field

    Search field is the field for search for a peripheral device.

    To select a search field

    1. Tap the Search Field list.

      The list of fields screen appears.

    2. Tap to select a field.

      The field is selected, and the peripheral device screen appears.

      The default value is Barcode for camera and NFC for NFC Reader.

      Note:
      - When you configure a Land Cyclops peripheral device, ensure:
      - - The Classic trigger function is set on the peripheral device.
      - - The Input Field, configured in the Management Center, matches the pin switches on the peripheral device. For example, if the pin switch is set to Peak, then you should select Maximum for the Input Field. Similarly, if the pin switch is set to Valley, then you should select Minimum for the Input Field.

      Advanced

      Advanced search/input device settings provide device specific settings to configure for a peripheral device. The following advanced settings are for the default supported peripherals:

      Land Cyclops 100L/390L

      Advanced settings for Land Cyclops provide device specific settings to configure for the peripheral device.

      Units of Measure

      Unit of measure governs the method of temperature measurement.

      Type 1 for Celsius and 0 for Fahrenheit.

      The default value is 0.

      Bluetooth Address

      Bluetooth address is provided for troubleshooting purposes only and should not be modified.

      Bluetooth PIN

      Bluetooth PIN is a number to pair a Bluetooth peripheral device with a mobile device.

      The default value is 0000.

      Timeout

      Timeout is the number of milliseconds the app will wait for a response from the peripheral device before trying again.

      The default value is 3000 milliseconds (3 seconds).

      Inter-char Timeout

      Inter-char timeout specifies the length of the delay between transmissions that is used to indicate the end of a message/input from the peripheral device.

      A smaller value can improve performance but may cause communications failures on slower or heavily loaded processors.

      The default value is 200 milliseconds (0.2 second).

      Update Rate

      Update rate specifies the rate at which data is updated from the peripheral device.

      The default value is 500 milliseconds (0.5 second), and the update rate should not be set lower than this value.

      Sleep Duration

      Sleep duration is the number of milliseconds that the peripheral device waits before taking another reading.

      The default value is 1000 milliseconds (1 second), and the sleep duration should not be set lower than this value.

      Raytek Raynger MX4 with Bluetooth

      Advanced settings for Raytek Raynger MX4 with Bluetooth provide device specific settings to configure for the peripheral device.

      Units of Measure

      Unit of measure governs the method of temperature measurement.

      Type 1 for Celsius and 0 for Fahrenheit.

      The default value is 0.

      Bluetooth Address

      Bluetooth address is provided for troubleshooting purposes only and should not be modified.

      Bluetooth PIN

      Bluetooth PIN is provided for troubleshooting purposes only and should not be modified.

      Timeout

      Timeout is the number of milliseconds the app will wait for a response from the peripheral device before trying again.

      The default value is 3000 milliseconds (3 seconds).

      Inter-char Timeout

      Inter-char timeout specifies the length of the delay between transmissions that is used to indicate the end of a message/input from the peripheral device.

      A smaller value can improve performance but may cause communications failures on slower or heavily loaded processors.

      The default value is 200 milliseconds (0.2 second).

      Update Rate

      Update rate specifies the rate at which data is updated from the peripheral device.

      The default value is 3000 milliseconds (3 seconds), and the update rate should not be set lower than this value.

      Sleep Duration

      Sleep duration is the number of milliseconds that the peripheral device waits before taking another reading.

      The default value is 10000 milliseconds (10 seconds), and the sleep duration should not be set lower than this value.

      TPI 9080/9085 Vibration Analyzer

      Advanced settings for TPI 9080/9085 Vibration Analyzer with Bluetooth provide device specific settings to configure for the peripheral device.

      Bluetooth Address

      Bluetooth address is provided for troubleshooting purposes only and should not be modified.

      Bluetooth PIN

      Bluetooth PIN is provided for troubleshooting purposes only and should not be modified.

      Timeout

      Timeout is the number of milliseconds the app will wait for a response from the peripheral device before trying again.

      The default value is 6000 milliseconds (6 seconds).

      Inter-char Timeout

      Inter-char timeout specifies the length of the delay between transmissions that is used to indicate the end of a message/input from the peripheral device.

      A smaller value can improve performance but may cause communications failure on slower or heavily loaded processors.

      The default value is 5000 milliseconds (5 seconds)

      Note: For TPI 9085, you must set the inter-char timeout as the Auto Settle Time + a minimum of 5000 milliseconds (5 seconds). For example, if the Auto Settle Time is 2 seconds, you must set the inter-char timeout as a minimum of 7000 milliseconds (7 seconds).

      Default Run Speed (in RPM)

      Run Speed Default specifies the default run speed setting, if not specified during integration.

      The default value is 1500 RPM.

      Display Run Speed

      Display Run Speed is specifies the display state of the run speed. Enter 1 to enable the display and 0 to disable the display.

      The default value is 0.

      Bartec RFID Pen

      Advanced settings for Bartec RFID Pen with Bluetooth provide device specific settings to configure for the peripheral device.

      Bluetooth Address

      Bluetooth address is provided for troubleshooting purposes only and should not be modified.

      Bluetooth PIN

      Bluetooth PIN is provided for troubleshooting purposes only and should not be modified.

      Timeout

      Timeout is the number of milliseconds the app will wait for a response from the peripheral device before trying again.

      The default value is 16000 milliseconds (16 seconds).

      Inter-char Timeout

      Inter-char timeout specifies the length of the delay between transmissions that is used to indicate the end of a message/input from the peripheral device.

      The default value is 500 milliseconds.

      Notes:
      -Device will automatically time out and switch off after 60 seconds.
      -User should place an RFID Tag near the Bartec RFID Pen for a successful read.

      AVEVA Mobile Operator Peripherals Windows SDK

      The AVEVA Mobile Operator Peripheral Windows SDK provides users the ability to use a new peripheral for procedure execution. This SDK helps to create a communication channel between the peripheral and AVEVA Mobile Operator App. For more information, see the AVEVA Mobile Operator Peripheral SDK Guide.

      Notes:

      - Make sure the peripherals Windows application is running before installing AVEVA Mobile Operator app. If AVEVA Mobile Operator app is installed prior to running the peripheral Windows application, you must restart the AVEVA Mobile Operator app, run the peripheral Windows application and then tap Refresh in the Search/Input Device screen.

      - The peripherals will only be available for search and input if the Windows application is running.

      - At this time, the SDK only supports development with .NET Framework for x64/86 architecture.