Procedure Conditions - Duplicate Sequence Numbers

  • Last UpdatedDec 03, 2020
  • 1 minute read

Provides a list of Procedure Conditions that contain duplicate sequence numbers.

When completing a procedure on a mobile device, the AVEVA Mobile Operator app may stop responding if the procedure contains tasks with multiple conditions having the same sequence number.

Resolution:

You may have to manually fix the Procedure Conditions with duplicate sequence numbers by performing the following steps:

  1. Open the Procedure from the Procedure Builder.

  2. Drag and drop the Condition to the last position within the same Task hierarchy.

  3. Select the Condition again and drag and drop it to the required position in the Procedure.

  4. Save and release the Procedure.

    The duplication of the sequence number is fixed, and the condition contains a unique sequence number.