Management Center Server Integration configuration
- Last UpdatedFeb 18, 2025
- 1 minute read
Note: Only a Tenant administrator with the required System Permission can create and update the WW Galaxy fields.
-
Open Management Center and access Procedure Builder’s List Manager as detailed in the Management Center documentation.
-
Open "Server Integration Configs" and create a new Configuration item under the "WW Galaxy Configurations" group.
-
Configure the following fields appropriately:
-
Server Name: The name of the server as it will appear in components of Procedure Builder. This option appears for all integrations.
-
Send Approved Only: If unchecked, values of Tasks using this integration are sent to the integration server on synchronization. If checked, these values are only sent after the Procedure Instance is marked "Approved" in Procedure Auditor Plus (see the Management Center User’s Guide" for more information regarding Auditor Plus).
-
Galaxy Name: The name of the Galaxy to which this Integration will connect. (This name is provided by ArchestrA IDE upon launch.)
-
Galaxy Repository Node: The computer name or IP address of the machine on which the Galaxy Repository is installed.
-
User: The username this Integration will use to login to ArchestrA.
-
Password: The password this Integration will use to login to ArchestrA.
-
Sleep Seconds: The interval at which the ArchestrA Update Service runs.
-
MX Read/Write TimeOut Seconds: The number of seconds that must elapse before a read or write to an ArchestrA attribute value fails due to timeout. Failed read operations will return a NULL, whereas failed write operations will log an error. Make sure the Galaxy WCF End Point Address is configured within the System Configurations module, under AVEVA Mobile Operator Settings.
-